GV Generators
Troubleshooting Voltage Issues
wc_tx000772gb.fm
17
2.2
Checking the Stator Windings
Prerequisites
Generator shut down
Multimeter
Procedure
Follow the procedure below to check the stator windings.
1. Remove the end cap
(a)
from the generator.
2. Disconnect the yellow (Y), red (R), black (B), and green (G) wires from the alter-
nator.
3. Measure the resistance in Ohms between the red and yellow wires. Also mea-
sure between the black and green wires. See chart below.
Is the correct resistance measured for your machine?
This procedure continues on the next page.
Machine
R–Y B–G
GV 2500A
0.9–1.4
0.9–1.4
GV 3800A
0.7–1.2
0.7–1.2
GV 5600A
0.4–0.9
0.4–0.9
GV 6600A
0.3–0.8
0.3–0.8
Yes ____
No ____
Continue.
The stator windings have failed. Replace the stator.