GV Generators
Troubleshooting Voltage Issues
wc_tx000772gb.fm
31
Continued from the previous page.
4. Disconnect the DC rectifier
(z)
.
5. Check across the terminals of the DC rectifier using the diode scale. Use the
terminal
(y)
where the BR-R wire connects as a base point. Measure between it
and the two other terminals. Reverse the leads of the meter and measure
again. The meter should read approximately 0.5V in one direction and OPEN or
“OL” in the other.
Does the DC rectifier function as stated above?
This procedure continues on the next page.
Yes ____
No ____
Your reading
The DC rectifier is OK; continue.
The DC rectifier has failed;
replace it.
wc_gr004370
z
wc_gr004372
d
1000
200
20
2
200m
F
V
A
V-
COM
y