3
Place a recovery container under the pump unit.
Attach a plastic hose to the drain screw and open
the screw on the filter cover and let the remainder
of the solution run into the recovery container.
4
Remove the hose from the filter cover by pressing
in the lock catches.
5
Remove the filter cover (1) from the pump unit.
Remove the filter (3).
NOTICE!
If the filter has been loosened it has to
be fully removed, even if it is to be reused, before
reinstalling it again.
6
Install a new O-ring (2) in the new filter cover.
Install a new filter with the filter cover.
Install filter and cover together into the pump.
Tighten the filter cover using a torque wrench.
NOTICE!
Check that the drain valve is tightened.
7
Reinstall the filter cover hose. Make sure that the
connection locks securely.