3.
Bypass
DiEntry is equipped with an automatic bypass. For more information on the bypass logic please refer
to the DiEntry Reseller manual (Chapter 7.4 Bypass).
The bypass valve is normally open. Close the bypass valve before troubleshooting.
To close the Bypass, remove the white/blue cable (blue cable shoe) from the valve connection and
connect the red cable (blue cable shoe).
NOTE:
Return the Bypass valve to its original state (white/blue cable connected) after troubleshooting.
4.
Alarms
If an alarm occurs, the alarm symbol
‘’!’’ will appear on the process s
tep screen.
OPERATION
100 uS/cm !
If an alarm occurs and the unit is equipped with a SIM card, an automated SMS will be sent with the
alarm code (for more information on alarms please refer to DiEntry reseller manual). This automated
procedure is valid for all the alarms except the PAE COMM ERR., I2C and Temp. ERR. alarms, these are
self-resolved and do not require any action or special troubleshooting, for this reason no SMS
response is trigged by the unit. The user can be notified for these alarms only via the daily summary
report e-mail. If a PAE alarm is persistent for a time period of one week please conduct Voltea.
The following chapters display a step by step troubleshooting procedure for every possible alarm. If
the issue is not identified during the first troubleshooting event, please continue to the next event
until the issue is identified. If all the steps are followed and the root cause of the alarm is not identified
please contact Voltea or an authorized reseller.
For spare parts and assistance, please contact Voltea ([email protected])
Bypass valve
Bypass line