15 |
P a g e
▪
o
Observe the LEDs on the chip
▪
LED on the bottom left corner should be blinking green during normal
operation. If this LED is blue, please replace the flow chip.
▪
LED on the bottom top right should be rotating. If the LED is not rotating during
normal operation, please replace the flow chip.
E.
Flow sensor
o
Open the electrical cabinet and check the flow sensor connections on the PCB. The
wires from the top to bottom should be : green
–
white
–
brown.
Flow sensor wiring
Содержание DiEntry
Страница 1: ...Step by Step Alarm Troubleshooting...