23 |
P a g e
B.
Check if the EC probe is properly connected.
o
Open the electrical cabinet.
o
Check the connections on the bottom right corner of the PCB as indicated below.
▪
The 2 pin connections should be connected to black and red starting from top
to bottom. Gently pull the wires to ensure tight connection.
▪
The 4-pin connection should be connected to brown
–
green
–
white-
yellow/blue wire, starting from top to bottom. Gently pull the wires to ensure
tight connections.
C.
Check the EC chip on the power board.
o
Open the cabinet door.
o
Locate the EC chip LEDs on the right-hand side of the cabinet.
o
The LEDs should be blue and red when the unit is not desalinating as seen on the
picture above. The blue LED should be blinking during normal operation. If the EC chip
LEDs are not as described above, please conduct Voltea.
Electrical conductivity chip LEDs