71
h) Resistance
Range
Resolution
Accuracy
600.0 Ω*
0.1 Ω
±(1.2 % + 3)
6.000 KΩ
0.001 KΩ
±(1.0 % + 3)
60.00 KΩ
0.01 KΩ
600.0 KΩ
0.1 KΩ
6.000 MΩ
0.001 MΩ
±(1.5 % + 3)
60.00 MΩ
0.01 MΩ
±(2.5 % + 6)
600 V overload protection
Measuring voltage: Approx. -2.8 V (60/600 Ω-measuring range), -1 V (other ranges)
Measuring current: Approx. -1.4 mA
*After discounting test lead resistance
i) Acoustic continuity tester
Measuring range
Resolution
99.99 Ω
0.01 Ω
≤10 Ω continuous tone; ≥100 Ω no tone
Overload protection: 600 V
Test voltage Approx. -3.2 V
Test current -1.4 mA