a) Direct voltage (V/DC)
Range
Resolution
Accuracy
6.000 V
0.001 V
±(0.6 % + 3)
60.00 V
0.01 V
±(0.9 % + 6)
600.0 V
0.1 V
600 V overload protection; Impedance: 10 MΩ
Specified measuring range: 5 – 100 % of the measuring range
b) Alternating voltage (V/AC)
Range
Resolution
Accuracy
6.000 V
0.001 V
±(1.0 % + 6)
60.00 V
0.01 V
600.0 V
0.1 V
600.0 V "LoZ"
0.1 V
±(2.5 % + 6)
600.0 V "Motor"
0.1 V
±(2.0 % + 6)
Frequency range: 40 Hz – 1 kHz ; 600 V overload protection; Impedance: 10 MΩ (LoZ: 300 kΩ)
Specified measuring range: 5 – 100 % of the measuring range
The multimeter may display ≤5 counts if a measuring input is short-circuited.
After using the LoZ feature, leave the multimeter for 1 minute before using it again.
TrueRMS peak (Crest Factor (CF)) ≤3 CF to 600 V
TrueRMS peak for non-sinusoidal signals plus tolerance
CF >1.0 – 2.0 + 3 %
CF >2.0 – 2.5 + 5 %
CF >2.5 – 3.0 + 7 %
Criteria for phase detection in "Motor" mode: >80–600 V/AC, 50–80 Hz