1
USERS INSTRUCTIONS
1.1 GAS APPLIANCES
Gas Safety (Installations and Use) Regulations (UK).
In the interests of your safety and that of others it is a legal
requirement that all gas appliances are installed and correctly
maintained by a competent person and in accordance with the
latest regulations.
1.2 ELECTRICAL SUPPLY
Please ensure that this appliance has been properly connected
to the electrical supply by means of a double pole isolator or
un-switched socket, and that the correct size of fuse (3 AMP)
has been fi tted.
Warning: this appliance must be earthed!
1.3 GUARANTEE REGISTRATION CARD
Please take the time to fi ll out your guarantee registration card.
The completed warranty card should be posted within 30 days
of installation.
1.4 APPLIANCE COMMISSIONING CHECKLIST
(UK only)
A checklist section can be found at the rear of the appliance
installation booklet. This important document must be com-
pleted during the installation/commissioning of your boiler. All
GAS SAFE registered installers carry a GAS SAFE ID card,
and have a registration number. These details should be re-
corded in the Benchmark commissioning checklist section
within the installation booklet. You can check your installers
details by calling GAS SAFE direct on 08004085500. Failure
to install and commission the appliance in accordance with
the manufacturers instructions will invalidate the warranty.
This does not affect your statutory rights.
1.5 HOW DOES IT WORK?
Your
Mynute
i
boiler supplies heated water to your radiators
and hot water to your hot water tank. The central heating is
controlled via a time clock and any thermostats that your installer
may have fi tted. The boiler will light when it receives a request
from the time clock via any thermostat that may be installed.
Your Mynute
i
boiler lights electronically and does not have a pilot
light. In the unlikely event of a fault developing with your boiler,
the supply of gas to the burner will be terminated automatically.
Dear Customer
Your Vokèra Mynute
i
boiler has been designed to meet and exceed the very latest standards in gas central heating technology,
and if cared for, will give years of reliable use and effi ciency.
Please therefore take some time to read these instructions carefully.
Do’s and Don’t’s
-
Do
ensure that the system pressure is periodically checked
-
Do
ensure that the boiler should not be used by children or unassisted disabled people
-
Do
ensure that you know how to isolate the appliance in an emergency
-
Do
ensure that you are familiar with the appliance controls
-
Do
ensure that your installer has completed the appliance log book section
-
Do not
attempt to remove the appliance casing or gain internal access
-
Do not
hang clothes etc. over the appliance
-
Do not
forget to have the appliance serviced annually.
This booklet is an integral part of the appliance. It is therefore necessary to ensure that the booklet is handed to the person re-
sponsible for the property in which the appliance is located/installed. A replacement copy can be obtained from Vokèra customer
services.
INTRODUCTION
1.6 DIMENSIONS
1.7 CLEARANCES REQUIRED
1.8 FROST PROTECTION SYSTEM
The
Mynute
i
is equipped with a built-in frost protection system,
this enables the boiler to over-ride the time controls – even if
switched off – and operate the burner and/or pump, should
the temperature drop below 5
0
C for the main. In particular the
burner will be in ON status until the main temperature reaches
35°C for CH appliance.
Please note that the frost protection system is designed to
protect the appliance only, should frost protection be required
for the heating system, additional controls may be required.
NOTE
The frost protection system is reliant on the appliance having a
permanent electrical supply, and being in a non-fault condition.
1.9 APPLIANCE STATUS INDICATORS
Your boiler is equipped with a large LCD display that indicates
the appliance operating status.
1. THINGS YOU SHOULD KNOW
Mynute
i20
Mynute
i30
HEIGHT
780 mm
780 mm
WIDTH
400 mm
400 mm
DEPTH
338 mm
388 mm
ABOVE
150 mm
BELOW
150 mm
LEFT SIDE
12 mm
RIGHT SIDE
12 mm
FRONT
600 mm
Содержание Mynute i20