3.1 HOW TO TOP-UP THE SYSTEM PRESSURE
(
fi
g. 1-2)
The system pressure must be checked periodically to ensure the
correct operation of the boiler. The needle on the gauge should
be reading between 1 and 1.5 BAR when the boiler is in an off
position and has cooled to room temperature. If the pressure
requires ‘topping-up’ use the following instructions as a guide.
- Locate the fi lling valve connections (usually beneath the
boiler, see fi g. 2).
- Attach the fi lling loop to both connections.
- Open the fi lling valve slowly until you hear water entering the
system.
- Close the fi lling valve when the pressure gauge (on the boiler)
reads between 1 and 1.5 BAR (see fi g. 1).
- Remove the fi lling loop from the connections.
3.2 HOW TO RESET THE APPLIANCE
When the red fault LED is illuminated, the appliance will require
to be reset manually. Before resetting the boiler, check what
action is required to be taken, using the information on the
fault code table below. Allow a period of two minutes to elapse
before rotate the mode selector knob across the
position
(see fi g. 1).
IMPORTANT
If the appliance requires to be reset frequently, it may be indica-
tive of a fault, please contact your installer or Vokèra Customer
Services for further advice.
3.3 HOW TO SHUT DOWN THE SYSTEM FOR SHORT
PERIODS
The system and boiler can be shut down for short periods by
simply turning the time clock to the off position. It is also advis-
able to turn off the main water supply to the house.
3.4 HOW TO SHUT DOWN THE SYSTEM FOR
LONG PERIODS
If the house is to be left unoccupied for any length of time –
especially during the winter – the system should be thoroughly
drained of all water. The gas, water, and electricity supply to
the house should also be turned off. For more detailed advice
contact your installer.
3.5 HOW TO CARE FOR THE APPLIANCE
To clean the outer casing use only a clean damp cloth. Do not
use any scourers or abrasive cleaners.
3. HOW TO...
Fig. 2
control
valve
temporary
connection
control
valve
supply pipe
double
check valve
fl ow/return
pipe
4.1 WHAT IF I SUSPECT A GAS LEAK
If you suspect a gas leak, turn off the gas supply at the gas
meter and contact your installer or local gas supplier. If you
require further advice please contact your nearest Vokèra offi ce.
4.2 WHAT IF I HAVE FREQUENTLY TO TOP-UP
THE SYSTEM
If the system regularly requires topping-up, it may be indicative
of a leak. Please contact your installer and ask him to inspect
the system.
4.3 WHAT IF THE APPLIANCE IS DUE ITS AN-
NUAL SERVICE
Advice for tenants only
Your landlord should arrange for servicing.
Advice for homeowners
Please contact Vokèra Customer Service
(0844 3910999 (UK)
or 056 7755057 (ROI)
if you would prefer a Vokèra service
engineer or agent to service your appliance. Alternatively your
local GAS SAFE registered engineer may be able to service
the appliance for you.
4.4 - WHAT IF I NEED TO CALL AN ENGINEER
If you think your boiler may have developed a fault, please contact
your installer or Vokèra Customer Services
(0844 3910999 (UK)
or 056 7755057 (ROI)
have all your details to hand including
full address and postcode, relevant contact numbers, and your
completed appliance log book.