ENG

IDEO

325 Ecowatt

Installation Manual

Summary of Contents for IDEO

Page 1: ...ENG IDEO 325 Ecowatt Installation Manual...

Page 2: ...Before manipulating this device disconnect the electricity supply During normal operation never stop the ventilation system...

Page 3: ...homes Soler Palau will not be held liable for damage produced by Misuse Normal wear and tear of components Non observance of the instructions contained in this manual regarding safety use and start up...

Page 4: ...d airflows are separated and filtered Only the energy from the extracted air is transferred to the new fresh air introduced Thanks to IDEO 325 Ecowatt s high efficiency heat exchanger performance can...

Page 5: ...avoid thermal losses and optimise the performance of the installation it is d d t i l t d t b f i th i recommended to use insulated tubes for moving the warm air Discharge extracted air to outside Th...

Page 6: ...2 3 Dimensions Central unit Weight 51 Kg Remote controls Programmable module Kitchen boost...

Page 7: ...Wall bracket 2 4 Placement On a vertical wall 300 On the floor It is recommended to locate IDEO in heated house space Otherwise it will be necessary to insulate the condensate drain pipework...

Page 8: ...An specific kit option Support NEVER FIT THE IDEO ON THE CEILING It is recommended to locate IDEO in heated house space Otherwise it will be necessary to insulate the condensate drain pipework Tube c...

Page 9: ...n Outlet roof caps CT 150 Toilets BDOP 125 BDOP 80 Toilets Air intake plenum 6 1 spigots PAP Air intake D150 Li i itti Or PAF 150 Circular Air intake wall hoods Living sitting room Bedrooms Or Or PAST...

Page 10: ...TYPE DISTRIBUTION Outlet roof caps CT 150 Living sitting room BDOP 125 Kitchen BDOP 125 BDOP D80 RD80 Bedrooms Toilets BAR Toilets PAP Air intake D150mm BDOP D80 RD80 Or PAF 150 Circular Air intake D...

Page 11: ...ximum power 230 Watts Max ambient temperature 50 C Max temperature of flows 45 C 45 C Do not start the central until all the ducts are all completely fitted Air inlet retaining grille or roof outlet s...

Page 12: ...attery The programming module is located on the front of the machine This remote control can also be located on a wall The programming module is located on the front of the machine This remote control...

Page 13: ...or large flow 6 By pass 7 Defrost mode 7 Defrost mode 8 Absence mode 9 Transmission reception level 10 Battery level 11 Default mode 12 Change filter 12 Change filter 13 Instant energy saving 14 Energ...

Page 14: ...h t di t th Adjust the minimum desired airflow using keys 19 and 20 in 5 m3 h steps according to the configuration of your house in compliance with the table Maximum airflow Validate with key 18 The p...

Page 15: ...ing the By pass 6 The by pass works automatically with this conditions Indoor temperature Outdoor temperature and Indoor temperature 24 C During the operation of the by pass the icon is displayed It s...

Page 16: ...ures Tin and Tout indicate the temperatures measured in Tin Temperature on the remote control Tout Temperature into the outdoor fresh air inlet Conditions for the filter icon to be displayed 12 This i...

Page 17: ...side temperature from the fresh air intake is 1 C or lower T e 1 c Yes No Intake Air 50 es Intake Air 100 2 minutes T e 1 c Yes No 2 minutes Air Intake 100 2 minutes 2 minutes Intake Air 25 2 minutes...

Page 18: ......