![VOKERA Maxin 24e Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/vokera/maxin-24e/maxin-24e_installation-and-servicing-instructions-manual_1044988005.webp)
4
MAXIN 24e & 28e
Working Pressures
Heating System
Hot Water System
Maximum
1.5bar/15m.wg/50ft wg
6.0bar/90psig
Minimum
0.5bar/5m.wg/16ft wg
0.6bar/7psig
Safety valve setting
3bar/30m/102ft
Flow Rates
Min. water flow (dhw) 2.8 litres/min (0.6 gal/min)
Min. central heating flow rate through appliance 350 litres/h (1.28 gal/min).
Gas Control Valve: Basic Honeywell VK4105A 1027 1 220/240v CVI (Combined Valve and Ignition)
This unit is modified. The modification comprises a coil carried by the main burner regulation screw. For
full flame a voltage of approx. 12.5v dc is applied to the coil. For central heating max. rate the max.
voltage to the coil is restricted by an on site adjustment of a potentiometer.
3.9
Nominal hot water production
3.10
Central Heating Pump Duty
Min. Gas Rate
Max. Gas Rate
3.27 m3/h 115.8 ft3/h
1.10 m3/h 39.0 ft3/h
28e
24e
3.12 Burner Details (N/G)
Burner Pressure Min. C/H
24e
28e
Polidoro NP12
Polidoro NP14
12 x 1.35
14 x 1.35
10.1 mbar
10.1 mbar
3.11 Gas Rates (N/G)
TEMPERATURE
RISE °C
35
30
11.3
9.7
11.5
13.4
24e
28e
FLOW RATE LITRES/MIN.
Fig. 3
Water
flow
l/h
Water
pressure
mbar
Burner Pressure Max.
1.9 mbar
1.6 mbar
Burner Pressure Min. DHW
Main Burner Injectors
Main Burner
1.5 mbar
1.3 mbar
1.02 m3/h 36.37 ft3/h
2.78 m3/h 98.3 ft3/h
P u m p p re s s u re
R e s id u a l P re s s u r e
B o ile r p r e s s u re lo s s
0
2 5 0
5 0 0
7 5 0
1 0 0 0
1 2 5 0
0
1 0 0
2 0 0
3 0 0
4 0 0
5 0 0
Содержание Maxin 24e
Страница 53: ...52 MAXIN 24e 28e GENERAL LAYOUT ILLUSTRATED WIRING DIAGRAM Fig 38...
Страница 57: ...Cod 10022256 19 01 Ed 1...