8.4
To Gain General Access/Assembly
To remove components access to the
interior is essential. Refer to fig. 24.
Ensure electricity supply is isolated before
carrying out any servicing.
8.4.1
To remove front casing.
Release 4 retaining screws fig. 24.
Pull bottom of case slightly forward and
push case upwards to disengage from top
support hooks and withdraw the case from
the appliance.
The control panel can now be hinged down
for access.
8.4.2
Reassembly is always carried out in reverse
order to dismantling, unless otherwise
stated. Electrical connections must be
remade in accordance with the wiring
diagram figs. 37 & 38.
8.4.3
Wherever gas control components are
replaced, check the burner pressures and
adjust if necessary (Section 8.23)
8.4.4
If required remove finger guard by remov-
ing 4 vertical screws and pull grill down-
wards (see fig. 18a).
8.5
Room Sealed Chamber Front Cover
Part No. 5904 Refer to fig. 25
8.5.1
Gain general access as 8.4
8.5.2
Remove room sealed front cover plate by
releasing eight screws fig. 25) and easing
cover off. The screws are not captive.
Inspect gasket for damage. If damaged,
replace.
NOTE: When refitting the Room sealed
chamber front cover it is essential to cor-
rectly seat and secure the cover in place
ensuring all screws are tightened.