![VOKERA Maxin 24e Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/vokera/maxin-24e/maxin-24e_installation-and-servicing-instructions-manual_1044988035.webp)
34
MAXIN 24e & 28e
YES
NO
NO
TEST A : CHECKING OPERATION OF
ELECTRONIC CONTROL BOARD
NO
YES
YES
NO
NO
REPLACE FLOW
SWITCH AND/OR
WIRING
CHECK WATER
FLOW
SWITCH AND
WIRING
OK
MAINS ON FUN
REPLACE FUN
YES
NO
NO
YES
REPLACE WIRING
OR CONNECTIONS
MAINS ON PUMP
REPLACE PUMP
YES
NO
YES
NO
YES
NO
YES
YES
A
IS
THERE MAINS
BETWEEN TERMINALS
M4.24 & M3.10
ON PCB
IS THERE
240Vac BETWEEN
TERMINALS M3.7 &
M1.23 ON
PCB
REPLACE WIRING
AND
CONNECTIONS
MAINS
ON FAN
CONNECTOR M4.28
& M4.24 ON
PCB
MAINS
ON PUMP
CONNECTOR
M1.22 &
M1.23
CHECK WIRING AND
CONNECTIONS BETWEEN
TERMINAL BLOCK AND
CIRCUIT BOARD
CHECK WIRING AND
CONNECTIONS OR HOT
WATER FLOW SWITCH
REPLACE PCB
REPLACE
CIRCUIT BOARD
REPLACE FUSE
FUSE OK
CHECK FUSE
ON CIRCUIT
BOARD
RECHECK SUPPLY
FUSE &
CONNECTORS TO
BOILER TERMINALS
IS
240V AC
PRESENT
BETWEEN LIVE &
NEUTRAL ON
TERMINAL
BLOCK
FAN RUNNING
PUMP RUNNING
TURN ON HOT TAP
SWITCH ON/OFF SELECTOR
TO DHW POSITION. DHW
THERMOSTAT MAX.
START
IS THERE
240Vac BETWEEN
TERMINALS M3.8 &
M1.23 ON
PCB
IS THERE
240Vac BETWEEN
TERMINALS M2.1 &
M2.5 ON
PCB
NO
YES
YES
YES
NO
NO
REPLACE
CIRCUIT BOARD
IS
THERE MAINS
BETWEEN TERMINALS
M4.24 & M3.9
ON PCB
NO
YES