MAXIN 24e & 28e
Bend Reduction in maximum flue length for
each bend
45º bend
1.0 metre
90º bend
1.0 metre
Part No.
Description
Length
0225805
Horizontal flue terminal
1.0 metre
0225810
Vertical flue terminal
1.0 metre
300
Twin adapter kit
N/A
0225770
Pitched roof flashing plate
N/A
0225765
Flat roof flashing plate
N/A
0225815
Condensate drain kit
N/A
0225820
0.25m extension (pair)
250mm
0225825
0.5m extension (pair)
500mm
0225830
1.0m extension (pair)
1000mm
0225835
2.0m extension (pair)
2000mm
0225840
45º bend (pair)
N/A
0225845
90º bend (pair)
N/A
0225850
Twin bracket (5)
N/A
0225855
Single bracket (5)
N/A
be given to the fact that there is the possibility
of a small amount of condensate dripping
from the terminal.
•••••
Ensure that the entire flue system is ad-
equately supported, use at least one
bracket for each extension.
•••••
The entire flue system must be adequately
insulated to maintain heat within the flue
system thereby reducing the possibility of
condensate production.
•••••
As the exhaust outlet pipe can reach very
high temperatures it must be protected to
prevent persons touching the hot surface.
Reduction for bend
Mounting the boiler
The fixing holes for the wall-mounting bracket
& jig should now be drilled and plugged, an
appropriate type and quantity of fixing should
be used to ensure that the bracket is mounted
securely. Once the bracket has been secured
to the wall, mount the appliance onto the
bracket & jig.
5.5.3.1
Installation of twin adaptor kit (fig. 15)
Twin flue accessories
Fig. 15
•
Remove or discard the flue restrictor ring
from the appliance flue outlet (see fig. 1).
•
Insert the small restrictor ring (supplied with
the twin adapter kit) if the total flue length –
including the allowance for any bends – is
less than 8 metres.
•
Insert the exhaust connection manifold onto
the appliance flue outlet.
•
Place the silicone seal (supplied with twin
adapter kit) over the rim of the exhaust
connection manifold.
⇑⇑⇑⇑⇑
Remove one of the blanking plates (located
to the left & right of the appliance flue outlet)
and – using the same screws – install the air
baffle.
5.5.3.2
Installation of condensate drain kit
(fig. 16)
Fig. 16
The condensate drain kit must be fitted within
1 metre of the appliance flue outlet. It is
recommended that the condensate drain kit
should be fitted in the vertical plane, however
it can be fitted horizontally with care.
•••••
Fit the first bend to the condensate drain kit
or exhaust connection manifold by firmly
pushing in to position.
•••••
Using the two holes in the exhaust connec-
tion manifold as a guide, drill a 3mm hole in
each and secure using the screws provided.
•
Connect the air inlet pipe to the air baffle as
above.
•
The twin flue pipes extensions and accesso-
ries can now be installed by pushing to-
gether (the plain end of each extension or
bend should be pushed approximately 50mm
into the female socket of the previous piece).
The condensate drain trap must be con-
nected to the drain in accordance with Build-
ing Regulations or other rules in force.
5.5.3.3
Horizontal termination ( fig. 17)
The twin flue system must be converted to the
dedicated concentric flue kit for termination.
•
The horizontal terminal is supplied with a
built-in converter box and cannot be
shortened.