11
MAXIN 24e & 28e
Fig. 13
Fig. 12
Insert the flue assembly into the previously
drilled flue hole and locate the flue bend over
the appliance flue outlet. Push the flue bend
down over the appliance flue outlet and ensure
the correct seal is made. Pull the flue assembly
towards and over the flue bend – using a
twisting action – ensuring the correct seal is
made. Check that the terminal protrudes past
the finished outside wall by the correct length
(115mm).
NOTE
You must ensure that the entire flue system is
properly supported and connected.
Seal the flue assembly to the wall using cement
or a suitable alternative that will provide
satisfactory weatherproofing. The interior and
exterior trim can now be fitted
FITTING THE STANDARD (2359029)
HORIZONTAL FLUE KIT (see 5.4.1)
Carefully measure the distance from the centre
of the appliance flue outlet to the face of the
outside wall (dimension ‘X’ see fig. 13). Ensure
the inner (60mm) pipe is fully inserted into the
outer (100mm) pipe (when the inner pipe is
fully inserted, it stands proud of the outer pipe
by 7.5mm). Add 32mm to dimension ‘X’ to give
the overall flue length (dimension ‘Y’). The
standard horizontal flue kit (part no. 2359029)
is suitable for a distance (dimension ‘Y’) of up
to 865mm.
NOTE
Dimension ‘Y’ is measured from the end of the
terminal to the end of the outer (100mm) pipe.
The internal trim should be fitted to the flue
pipe before connection of the 90º bend.
If the horizontal flue kit (2359029) requires to
be cut to the correct size (dimension ‘Y’), you
must ensure that the inner (60mm) pipe stands
proud of the outer (100mm) pipe by 7.5mm
(see fig. 13A). Ensure any burrs are filed or
removed and that any seals are located
properly before assembly.
Connect the inner (60mm) pipe of the terminal
assembly to the push-fit end of the 90º bend
(supplied) using a twisting action. Insert the
assembled flue into the previously drilled hole.
Using the clips & screws supplied, connect the
flue assembly to the boiler, ensuring that the
terminal protrudes past the finished outside
wall by the correct length (135mm).
You must ensure that the entire flue system is
properly supported and connected.
Seal the flue assembly to the wall using cement
or a suitable alternative that will provide
satisfactory weatherproofing. The exterior
trim can now be fitted.
EXTENDING THE HORIZONTAL FLUE
If the horizontal flue requires extension/s or
additional bend/s, the horizontal flue terminal
kit (2359029) must be used. Connect the
bend – supplied with the terminal kit – to the
top of the boiler using the clips, screws, &
gaskets supplied. The additional bends &
extensions have an internal push-fit
connection, care should be taken to ensure
that the correct seal is made when assembling
the flue system. Connect the required number
of flue extensions or bends (up to the maximum
equivalent flue length) to the flue terminal
using the clips, screws, & gaskets supplied
(see fig. 13 & 13A).
IMPORTANT
The flue restrictor ring (see fig. 1) must be
removed or discarded if the total flue length –
including bends – exceeds 1.0m.
NOTE
When cutting the horizontal flue terminal or an
extension to the required length, you must
ensure that the excess is cut from the plain
end of the terminal or extension, and that the
inner (60mm) pipe is 7.5mm longer than outer
(100mm) pipe (see fig. 13 & 13A). Remove
any burrs, and check that any seals are located
properly.