30
MAXIN 24e & 28e
8.21.10
Remove microswitch cover by unscrewing
3 securing screws & disconnect electrical
connections within.
8.21.11
Reassemble in reverse order ensuring
correct location of electrical connections.
(see fig. 38 for electrical connections)
8.21.12
Printed Circuit Board
Part No. 8481
8.21.13
Gain general access as 8.4 & remove finger
guard as 8.4.4.
8.21.14
Remove three control knobs from front of
control panel (pull off).
8.21.15
Remove printed circuit board cover by
releasing 4 securing screws.
8.21.16
Pull out 7 multi plug connectors from the
printed circuit board.
8.21.17
Remove 3 screws securing circuit board to
front panel and remove board.
8.21.18
Reassemble in reverse order ensuring
correct location of electrical connections.
(see fig. 38 for electrical connections)
NOTE: It will also be nesasary to check/
adjust the soft light, minimum rate for c/h &
range rating settings as cl. 8.23.3 to 8.23.5.
8.21.19
Safety & Fan Overrun Thermostats
Part No's 8367 & 4931 Refer fig. 33a
8.21.20
Gain general access as 8.4.
8.21.21
Pull off the two electrical connections on
the back of the thermostat.
8.21.22a SAFETY THERMOSTAT.
Release stat from flow pipe by unscrewing
2 retaining screws.
8.21.22b FAN OVERRUN THERMOSTAT
Release stat from flow pipe by pulling off
securing clip.
8.21.23
Reassemble in reverse order ensuring
correct location of electrical connections.
(see fig. 38 for electrical connections)
8.21.24
Thermistor Sensor
Part No. 8484 Refer to fig. 33
8.21.25
Gain general access as 8.4.
8.21.26
Close heating flow and return valves (fig.
6a) by turning butterfly top 1/4 turn until
head is 90° to the valve body.
8.21.27
Drain appliance via safety valve by ¼ turn
of safety valve knob.
8.21.28
Pull off electrical plug connection from
thermistor.
8.21.29
Unscrew thermistor from flow tube.
8.21.30
Reassemble in reverse order.
8.22
Combined Pressure & Temperature
Gauge
Part No 8809
8.22.1
Gain general access 8.4
8.22.2
Close heating flow and return valves (fig.
6a) by turning butterfly top 1/4 turn until
head is 90° to the valve body.
8.22.3
Drain appliance via safety valve by 1/4 turn
of safety valve knob.
8.22.4
Trace capillary from back of pressure
gauge to connecting point on brass mani-
fold.
8.22.5
Unscrew retaining nut and pull out capillary
tube from manifold.
8.22.6
Trace capillary tube from back of tempera-
ture gauge to sensor on flow pipe.
8.22.7
Ease off sensor retaining clip.
8.22.8
Squeeze plastic locking lugs behind fascia
and press gauge from aperture.
8.22.9
Reassemble in reverse order following
original route for capillary tubes and ensur-
ing locking lugs are located in the grooves.
Fig. 34
MODULATOR
COIL
SPRING
LOCKNUT
BRASS
SLEEVE
RETAINING CLIP
MINIMUM RATE
ADJUSTING
SCREW
Fig. 33a
Safety
Thermostat
Fan Overrun
Thermostat
Содержание Maxin 24e