MAXIN 24e & 28e
SECTION 3
TECHNICAL DATA
3.1
Units Dimensions and values are given in
the preferred Sl Units with Imperial units in
brackets where applicable.
3.2
Dimensions and Contents
Height 820mm (32.2in) appliance only.
980mm (38.7in) inc.horizontal flue.
Width: 450mm (17.7in)
Depth: 322mm (12.6in)
Weight empty 49kg (108lb)
full 52kg (114lb)
Water content: 3 litres (.66 gals)
for further dimensions see figs 12 - 16
3.3
Connection sizes
Heating flow and return: Threaded tail for
22mm bent tap connector (supplied).
Cold water inlet: Nut and olive for 15mm
o.d.
Hot water outlet: Nut and tail for 15mm
compression or capillary.
Gas Service: Rc ½ (½in BSP int)
Safety valve outlet: 15mm compression or
capillary.
Flue outlet/Air inlet: nom dia 60/100mm
specially supplied with boiler (concentric).
Flue outlet/Air inlet: nom dia 80/80mm
specially supplied with boiler (twin).
3.4
Installation Requirements
3.4.1
Clearances (Horizontal or Vertical Flue)
Minimum - above casing 225mm (9in)
Minimum - below casing 200mm (8in)
Minimum - In front 600mm (24in)
Minimum - At sides 12mm (½in) from
casing)
3.4.2
Maximum heating system contents approx.
76.4 litres (16.8 gals) Acceptance capacity
of expansion vessel 8 litres (1.8 gals).
3.4.3
Means of filling sealed system: To accord
with BS and/or local Water Authority re-
quirements.
3.4.4
The standard concentric horizontal flue
allows a maximum length of duct as fol-
lows:
Rear flue: 731mm (wall thickness)
Side flue: 890mm (to centre line of boiler).
Using extension tubes the flue may be
extended to the following lengths.
Concentric
24e: 4.5 metres max. (horizontal)
28e: 3.4 metres max. (horizontal)
24e 5.25 metres max. (vertical)
28e 4.4 metres max. (vertical)
Twin
24e & 28e 14/14 metres max. (horizontal)
24e & 28e 14/14 metres max. (vertical)
plus the horizontal or vertical concentric
terminal.
The reduction in flue length for each bend
used is listed opposite.
3.5
Electrical Details
Mains supply 230v ~ 50Hz Fused 3A
Internal fuse rating F2A
Power consumption: 125w.
3.6
Performance and Limitations 24e
Max. input 26.3 kW (89,735 Btu/h)(net)
Min. input 11.2 kW (38,225 Btu/h)(net)(c/h)
Min. input 9.8 kW (33,447 Btu/h)(net)(h/w)
Max. input 29.2 kW (99,658 Btu/h)(gross)
Min. input 12.4 kW (42,320 Btu/h)(gross)(c/h)
Min. input 10.8 kW (36,860 Btu/h)(gross)(h/w)
Max. output 23.7 kW (80,864 Btu/h)
Min. output 9.3 kW (31,740 Btu/h)(c/h)
Min. output 8.1 kW (27,645 Btu/h)(h/w)
Central Heating output range
Max. 23.7 kW (80,864 Btu/h)
Min. 9.3 kW (31,740 Btu/h)
3.7
Performance and Limitations 28e
Max. input 31.0 kW (105,802 Btu/h)(net)
Min. input 11.9 kW (40,614 Btu/h)(net)(c/h)
Min. input 10.5 kW (35,836 Btu/h)(net)(h/w)
Max. input 34.4 kW (117,406 Btu/h)(gross)
Min. input 13.2 kW (45,051 Btu/h)(gross)(c/h)
Min. input 11.6 kW (39,590 Btu/h)(gross)(h/w)
Max. output 28.0 kW (95,563 Btu/h)
Min. output 9.9 kW (33,788 Btu/h)(c/h)
Min. output 8.7 kW (29,692 Btu/h)(h/w)
Central Heating output range
Max. 28.0 kW (95,563 Btu/h)
Min. 9.9 kW (33,788 Btu/h)
3.8
Designed temp rise 20°C
Max. flow temperature 85°C
Fig.22 shows the relation between burner
pressure and input/output (N/G).
NOTE: Use gross input values when gas
rating the appliance (N/G).
3.8.1
L.P.G. instructions are to be found on pages
57 & 58.
BEND
90°
45°
REDUCTION IN FLUE
LENGTH FOR EACH
BEND
1000 mm
500 mm
CONCENTRIC FLUE:
BEND
90°
45°
REDUCTION IN FLUE
LENGTH FOR EACH
BEND
1000 mm
1000 mm
TWIN FLUE: