Rotary lobe pump
Operating instructions
VX100Q, VX136Q..QD..QDM2, VX186Q..QD..QDM2, VX230Q..QD
51/68
8.9
Change of cartridge mechanical seal
Material Duronit for seal rings
Mechanical seals made of 'Duronit' can only be used up to an operating pressure of 10 bar. Please note the
maximum operating pressure
Chap.
“Technical data".
8.9.1
Change of cartridge mechanical seal on the gearbox
Fig.
“Cartridge mechanical seal on the gearbox"
1.
Depressurize the buffer chamber (with QD pumps, both buffer chambers).
2.
Empty and clean the buffer chamber on the gearbox.
3.
Remove any flushing connections and circulation system
chap.
"Circulation system on the cartridge
mechanical seal” and
Fig.
“Flushing operation".
4.
Drain gearbox oil.
5.
Work steps
chap.
"Perform “Rotary lobe change and wear plate change”.
6.
Remove hex socket set screws (a) of the cartridge mechanical seal (Fig. a)).
7.
Put on cartridge installation tool (D) and screw the hexagonal socket screws (b) into the borings of the
cartridge mechanical seal (fig. b)).
8.
Smoothly pull out cartridge mechanical seal using the three hex head screws (c) of the installation tool
(Fig. b)).
9.
Change O-ring (30) in the bearing seal housing (fig. c)).
10.
Carefully remove the burrs on the keyways and clean the cartridge sealing ring seat in the housing
before installing the new cartridge sealing ring.
11.
Push new cartridge mechanical seal onto the shaft. Carefully oil the outer O-rings on the seal carrier
(Pos. 34 in fig. b)) before installation. Attention! Do not use oil for EPDM O-rings!
12.
If a circulation system is present, the bore holes in the cartridge mechanical seal must be aligned with
the flushing connections in the bearing seal housing.
13.
To install the new cartridge mechanical seal, place the installation tool on the cartridge mechanical
ring without screws.
14.
Push rotary lobe without key on the shaft.
15.
Insert the pressure disk and the strain screw.
16.
Tighten the rotary lobe until the cartridge mechanical seal is flush with the pump housing.
17.
Reinstall any removed flushing connections.
18.
Remove rotary lobe again.
19.
Push O-ring and support ring onto the shaft.
20.
Before installing the new rotary lobes, clean contact surfaces of rotary lobes and sealing components
very carefully.
21.
Install rotary lobes, wear plates and Q cover or QD cover.
22.
Top up buffer fluid.
23.
Readjust pressure in the buffer chamber (for QD pumps in both buffer chambers).
24.
Fill up the gearbox oil.
Содержание VX Series
Страница 1: ...Best Practices for Installation of VX Rotary Lobe Pumps WELCOME TO VOGELSANG FACTORY TRAINING ...
Страница 6: ...Follow all best practices for safety when working on Vogelsang Equipment Preparing for Installation ...
Страница 15: ...Installation ...
Страница 24: ...Pressurizing the Pump ...
Страница 36: ...Direction of flow Startup Checklist Startup ...
Страница 44: ......
Страница 121: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 122: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 123: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 133: ...Service Manual Service Manual Pump Models VX Series Q Pumps Operational Startup Testing continued ...
Страница 189: ...Service Manual Service Manual Pump Models VX Series Q Pumps Warranties 4 A 1 Warranty Information ...
Страница 191: ...Service Manual Service Manual Pump Models VX Series Q Pumps 5 A 1 Documents for Testing at Initial Startup continued ...
Страница 192: ...Service Manual Service Manual Pump Models VX Series Q Pumps 5 A 1 Documents for Testing at Initial Startup continued ...