![Vogelsang VX Series Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/vogelsang/vx-series/vx-series_manual_1044344065.webp)
Rotary lobe pump
Operating instructions
VX100Q, VX136Q..QD..QDM2, VX186Q..QD..QDM2, VX230Q..QD
21/68
5.4.1
Suction lines
To protect from high pressure losses and cavitation, heed the advice for laying the
suction lines
•
The maximum suction height is 8 m. This is the maximum distance between the lowest and highest
points of the suction pipe. Observe NPSH.
•
Suction lines whose diameter is too small may restrict the suction capability of the pump. Caution
cavitation hazard!
If the diameter of the suction pipe is too small, the maximum suction height will be reduced by
the loss of pressure due to pipe friction. Contact us for a calculation
.
•
Suction lines over 30 m must be laid with a slope of at least 2 x pipe diameter in the direction of flow,
ensuring that the pipeline can never run dry
Fig.
“Long suction lines".
Fig.
15
: Long suction lines
5.4.2
Discharge pipes
Risk of injury from bursting parts and medium spraying out under high pressure
•
Follow recommendations for pipes. Only use high-pressure pipes on the discharge side:
up to
nominal diameter DN 150 - PN 16 (bar) pipes
from
nominal diameter 200 - PN 10 (bar) pipes, except when the permissible operating
pressure of the pump unit is
≥ 10 bar
If you are uncertain about anything, please contact us
.
•
During periods of inactivity and periods of hot weather, fermentation may occur in closed pipelines.
The resulting gas can result in a large pressure increase that can damage the pump or pump unit and
cause injury. Therefore, ensure that no medium is left in the pump.
•
A connection
with sight glass
has to be installed on the suction side. If the sight glass is on the
discharge side (during reverse pumping), the pressure may not exceed 2 bar
Fig.
“Flow direction
with pump units".
Содержание VX Series
Страница 1: ...Best Practices for Installation of VX Rotary Lobe Pumps WELCOME TO VOGELSANG FACTORY TRAINING ...
Страница 6: ...Follow all best practices for safety when working on Vogelsang Equipment Preparing for Installation ...
Страница 15: ...Installation ...
Страница 24: ...Pressurizing the Pump ...
Страница 36: ...Direction of flow Startup Checklist Startup ...
Страница 44: ......
Страница 121: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 122: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 123: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 133: ...Service Manual Service Manual Pump Models VX Series Q Pumps Operational Startup Testing continued ...
Страница 189: ...Service Manual Service Manual Pump Models VX Series Q Pumps Warranties 4 A 1 Warranty Information ...
Страница 191: ...Service Manual Service Manual Pump Models VX Series Q Pumps 5 A 1 Documents for Testing at Initial Startup continued ...
Страница 192: ...Service Manual Service Manual Pump Models VX Series Q Pumps 5 A 1 Documents for Testing at Initial Startup continued ...