Rotary lobe pump
Operating instructions
VX100Q, VX136Q..QD..QDM2, VX186Q..QD..QDM2, VX230Q..QD
64/68
12.6 VX230
– Specifications
Pump size of
series:
theoretical
capacity*
max. operating
pressure**
theoretical operating torque with max.
operating pressure and water
VX230
n
max
= 540 [min
-1
]
VX..QD
VX..Q
VX..QD
VX..Q
[l]
[m
3
/h]
[bar]
[bar]
[Nm]
[Nm]
226
13.45
435
12
8
2900
2000
320
19.04
615
10
5
3470
1960
640
38.08
1230
6
-
4260
-
Free passage
For the VX230 series the maximum free passage is Ø 75 mm.
*
All data refer to theoretical capacity. The actual capacity is lower; it depends on the various operating
conditions.
**
Valid only for short operation times. For continuous operation, please contact our Service department
.
The service life of the rotary lobes is reduced by high temperatures, especially in combination with
high pressure.
Содержание VX Series
Страница 1: ...Best Practices for Installation of VX Rotary Lobe Pumps WELCOME TO VOGELSANG FACTORY TRAINING ...
Страница 6: ...Follow all best practices for safety when working on Vogelsang Equipment Preparing for Installation ...
Страница 15: ...Installation ...
Страница 24: ...Pressurizing the Pump ...
Страница 36: ...Direction of flow Startup Checklist Startup ...
Страница 44: ......
Страница 121: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 122: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 123: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 133: ...Service Manual Service Manual Pump Models VX Series Q Pumps Operational Startup Testing continued ...
Страница 189: ...Service Manual Service Manual Pump Models VX Series Q Pumps Warranties 4 A 1 Warranty Information ...
Страница 191: ...Service Manual Service Manual Pump Models VX Series Q Pumps 5 A 1 Documents for Testing at Initial Startup continued ...
Страница 192: ...Service Manual Service Manual Pump Models VX Series Q Pumps 5 A 1 Documents for Testing at Initial Startup continued ...