Service Manual
Service Manual
Pump Models:
VX Series Q Pumps
Special Tool Required
Some pumps are equipped with
plastic caps to protect the lobe
retention bolts (strain screws).
If your pump is equipped with
these plastic covers, simply pry
them loose with a flathead
screwdriver, and discard (
Fig. 4
).
Note:
The caps are not required
for proper pump operation.
Insert the strain bolt socket
provided with the optional lobe
puller. With the lobes blocked so
they will not rotate, loosen the
lobe retention bolts. They will be
very tight, so take care not to
strip them. The bolt will loosen
from the shaft, then seem to turn
freely in the hole (
Fig. 5
).
Note:
It is very easy to strip the
strain bolt heads. Take care to
use correct tools for this
operation.
Strain Bolt Wrench:
Part # WIN.002
Fig. 4
Fig. 5
Содержание VX Series
Страница 1: ...Best Practices for Installation of VX Rotary Lobe Pumps WELCOME TO VOGELSANG FACTORY TRAINING ...
Страница 6: ...Follow all best practices for safety when working on Vogelsang Equipment Preparing for Installation ...
Страница 15: ...Installation ...
Страница 24: ...Pressurizing the Pump ...
Страница 36: ...Direction of flow Startup Checklist Startup ...
Страница 44: ......
Страница 121: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 122: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 123: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 133: ...Service Manual Service Manual Pump Models VX Series Q Pumps Operational Startup Testing continued ...
Страница 189: ...Service Manual Service Manual Pump Models VX Series Q Pumps Warranties 4 A 1 Warranty Information ...
Страница 191: ...Service Manual Service Manual Pump Models VX Series Q Pumps 5 A 1 Documents for Testing at Initial Startup continued ...
Страница 192: ...Service Manual Service Manual Pump Models VX Series Q Pumps 5 A 1 Documents for Testing at Initial Startup continued ...