Rotary lobe pump
Operating instructions
VX100Q, VX136Q..QD..QDM2, VX186Q..QD..QDM2, VX230Q..QD
38/68
7.6
Oils and lubricants
1
Standard Vogelsang oil for pump gearboxes and buffer chamber
Part number
BSS.006
Description
EP (Extreme Pressure) gear oil
Trade name (Fuchs)
Titan Gear MP 90
Characteristics
Test acc. to
SAE class
90 (85W-90)
DIN 51512 or SAE J306c
Kinematic viscosity
at 40°C
at 100°C
198 mm²/s
17.3 mm²/s
DIN 51562
Flash point
215°C
DIN ISO 2592
Pour point
-18°C
DIN ISO 3016
Water hazard class
Slightly hazardous to
waters
2
Alternative oils for pump gearboxes and buffer chamber
Part number
BSS0021*
Description
Fully synthetic industrial gear oil based on poly-alpha-
olefins
Trade name (Fuchs)
Renolin Unisyn CLP
Characteristics
Test acc. to
ISO VG
220
DIN 51519
Kinematic viscosity
at 40°C
at 100°C
220 mm²/s
26.7 mm²/s
DIN EN ISO 3104
Flash point
260°C
DIN ISO 2592
Pour point
-42°C
DIN ISO 3016
Water hazard class
Slightly hazardous to
waters
*
when using BSS0021 oil for the pump gearbox, the maintenance interval
for inspection and gear oil change may be doubled
Chapter
"Maintenance plan“.
Part number
BSS.010**
Description
Medical white oil: water-white, non-fluorescent,
tasteless and odourless mixture of hydrocarbons
Trade name (Fuchs)
White oil W 530 (PH.EUR.)
Characteristics
Test acc. to
Kinematic viscosity
at 20°C
at 40°C
at 100°C
238 mm²/s
68 mm²/s
8.4 mm²/s
DIN 51562
Flash point
230°C
DIN ISO 2592
Pour point
-24°C
DIN ISO 3016
Ambient temperature
-
20°C…+40°C
Water hazard class
Slightly hazardous to
waters
**
BSS.010
oil is not permitted for high performance applications and continuous operation
over a maximum of 50% of the permitted pump pressure. Please contact us.
Sealing system with mechanical seal ring made of Duronit
If a mechanical seal ring made of Duronit is used in the sealing system, the damage loading step for the
buffer chamber oil must be
12
.
Содержание VX Series
Страница 1: ...Best Practices for Installation of VX Rotary Lobe Pumps WELCOME TO VOGELSANG FACTORY TRAINING ...
Страница 6: ...Follow all best practices for safety when working on Vogelsang Equipment Preparing for Installation ...
Страница 15: ...Installation ...
Страница 24: ...Pressurizing the Pump ...
Страница 36: ...Direction of flow Startup Checklist Startup ...
Страница 44: ......
Страница 121: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 122: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 123: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Страница 133: ...Service Manual Service Manual Pump Models VX Series Q Pumps Operational Startup Testing continued ...
Страница 189: ...Service Manual Service Manual Pump Models VX Series Q Pumps Warranties 4 A 1 Warranty Information ...
Страница 191: ...Service Manual Service Manual Pump Models VX Series Q Pumps 5 A 1 Documents for Testing at Initial Startup continued ...
Страница 192: ...Service Manual Service Manual Pump Models VX Series Q Pumps 5 A 1 Documents for Testing at Initial Startup continued ...