VKI Publication #100308-003
101
Code
Message Displayed
Condition
Action(s) Required
H1
Heater's current is close to critical
level
Heater current is close to maximum
operating level. Heater may be
drawing too much power.
1 - Inspect wiring and connections
to the heater relay and heater
element.
2 - Heater element may be drawing
too much power. If message
persists, replace the heater element.
Heater's current is close to minimum
operation level
Heater current is close to minimum
operating level. Heater may not be
drawing enough power.
1 - Reboot the machine.
2 - If message persists, replace the
heater element.
Heater's current is over safety level Heater current has exceeded the
maximum operating level.
1 - Inspect wiring and connections
to the heater relay and heater
element.
2 - Heater element may need to be
replaced.
3 - Heater relay may need to be
replaced.
Heater's current is under minimum
operation level
Heater current is below the
minimum operating level.
1 - Check wiring and connections to
the heater relay.
2 - Check wiring and connections to
the heater element.
3 - Replace heater element.
Water Tank Default
Critical Min Temp
Water temperature went below the
configured minimum critical
temperature (Default 0 C).
1 - Clear the message.
2 - Reboot the machine.
Water Tank Default Fill
Heating Time
Inlet valve and heater were both
activated for a period of time longer
than the configured timeout.
1 - Clear the message.
2 - Reboot the machine.
Water Tank Heating
Timeout
Reaching the water set point
(Default 95°C) took longer than the
maximum configured heating
timeout (Default: 30 min.)
1 - Clear the message.
2 - Reboot the machine.
3 - If message persists, replace the
heater element.
Water Tank Heating Probe
Error
Heater bad connection count has
exceeded the configured limit.
1 - Clear the message.
2 - Reboot the machine.
Water temperature is over the
maximum level
Water temperature has exceeded
configured temperature setting.
1- Heater relay may need to be
replaced.
2 - Control board may need to be
replaced.
K1 Fan is not present or has abnormal
operation
Fan is not present or operating
abnormally.
1 - Check fan wiring and connection
to the control board.
2 - Clean any accumulation from fan.
3 - If message persists, replace the
exhaust fan.
4 - If message persists, replace the
control board.
L4
Water Tank Level Error
Safety level probe is detected while
the normal level probe is not.
1 - Check wiring and connections to
the level probes.
2 - Clean level probes.
L5
The water level is reaching the
safety level probes
The water tank has overfilled and
the water level is reaching the safety
level probe.
1 - If this occurs during initial
heating, it may be due to water
expansion. Empty some water from
tank.
2 - The machine may have been
moved causing tank to overfill.
Empty some water from tank.
3 - Level probes require cleaning.
MDB1
Cash Box Full
The cash box in the changer housing
is full.
1 – Empty the cash box.
2 – Reset the Cash Box counter.
Coin Changer…(various messages)
Miscellaneous Coin Changer-related
issues.
Consult the coin changer
manufacturer’s documentation.