VKI Publication #100308-003
102
Code
Message Displayed
Condition
Action(s) Required
M1,
M2,
M3
Powder Dispensers current is close to
critical level
Powder Dispenser current is close to
maximum operating level. Powder
motor may be drawing too much
power.
1 - The powder product in the
dispenser may be packed or
compressed. Empty the dispenser.
2 - The dispenser may be jammed.
3 - The dispenser motor may be
seized. Try to unseize the motor.
4 - If message persists, replace the
powder dispenser motor.
Powder Dispensers current is close to
minimum operation level
Powder Dispenser current is close to
minimum operating level. Powder
motor may not be drawing enough
power.
1 - Check the wiring and
connections to the powder
dispenser motor.
2 - The powder dispenser may not
be engaged properly with the
powder dispenser motor.
3 - The powder dispenser motor
coupling may need to be replaced.
4 - If message persists, replace the
powder dispenser motor.
Powder Dispensers current is over
safety level
Powder Dispenser current has
exceeded the maximum operating
level.
1 - The powder in the dispenser may
be packed or compressed. Empty
the powder dispenser.
2 - Powder dispenser may be jammed.
3 - The powder dispenser motor may
be seized. Try to free the motor.
4 - If message persists, replace the
powder dispenser motor.
Powder Dispensers current is under
minimum operation level
Powder Dispenser current is below
the minimum operating level.
1 - Check the wiring and
connections to the powder
dispenser motor.
2 - If message persists, replace the
powder dispenser motor.
M4,
M5,
M11
Whippers current is close to critical
level
Powder Whipper current is close to
maximum operating level.
1 - If message persists, replace the
faulty whipper motor.
Whippers current is close to minimum
operation level
Powder Whipper current is close to
minimum operating level.
1 - If message persists, replace the
faulty whipper motor.
Whippers current is over safety level
Powder Whipper current has
exceeded the maximum operating
level.
1 - If message persists, replace the
faulty whipper motor.
Whippers current is under minimum
operation level
Powder Whipper current is below
the minimum operating level.
1 - Check the wiring and
connections to the whipper motor.
2 - If message persists, replace the
faulty whipper motor.
M6,
M7
Coffee Dispensers current is close to
critical level
Coffee Dispenser current is close to
maximum operating level.
1 - The dispenser may be jammed.
2 - The coffee dispenser motor may
be seized.
3 - If message persists, replace the
coffee dispenser motor.
Coffee Dispensers current is close to
minimum operation level
Coffee Dispenser current is close to
minimum operating level.
1 - Check the wiring and
connections to the dispenser motor.
2 - The coffee dispenser may not be
engaged with the dispenser motor.
3 - The coffee dispenser motor
coupling may need to be replaced.
4 - If message persists, replace the
coffee dispenser motor.
Coffee Dispensers current is over
safety level
Coffee dispenser motor current has
exceeded the maximum operating
level.
1 - Check to see if the coffee
dispenser motor is jammed.
2 - Reboot the machine.
3 - If message persists, replace the
coffee dispenser motor.