Technical Reference
Manual-XPM3m Revision Date: August 2014
CELL FAN MOTORS
Each cell is fitted with a convection motor and fan assembly. The motor is a three-phase, 1/6-hp unit. The motor
and fan assemblies are dynamically balanced to reduce vibration. On some ovens, an inverter is used to control the
operating speed of the motors.
The convection cell motors have a thermal cutout switch installed internally. If the motor exceeds its maximum
operating temperature (155° C), the cutout switch will “open” and the motor will not run. If the cutout is “open”, it will
be necessary to let the motor cool down before attempting to restart it. During normal operations, the motor should
not reach temperatures that cause the cutout to “open”. The upper and lower banks of cell fans are protected by
circuit breakers.
The motor supply voltage may be derived from a three Phase step-down transformer. The inputs and outputs of
this transformer are protected by circuit breakers.
TEST PROCEDURE FOR MOTOR RESISTANCE
With power off to the oven, disable the circuit breakers to the motors (top and bottom).
Using an Ohmmeter on its lowest scale, measure the resistance between each phase leg of the motor loads.
Using an Ohm meter check for short to ground (between each phase leg and the motor housing)
The resistance measured between each pair of phase legs should be approximately the same. If the resistance of
one phase leg is significantly different from the other two, either there is a defective motor (short in the windings) or
one of the motors is incorrectly connected.
CELL FAN MOTOR ROTATION CHECK
Create a recipe to activate the cell fans only. Start the recipe and observe the rotation of each motor. During normal
operation, the heat slinger fan turns counter clockwise as viewed from the outside of the cell. If a group of motors
(top or bottom) is not turning in the correct direction, de-activate the cell fan motors via the computer (stop recipe).
Shut off motor circuit breaker (F8) and swap two phase leads at
one
of the following locations:
- The Load side of K13. (to change rotation of ALL fans),
or
the load side of F41, F42, F43, F44. (to change rotation
of all Upper or Lower fans),
or
for an individual Fan Motor rotating backwards, swap any 2 power leads to the Fan
Motor at the Cell terminal Block.
(Do NOT move the Green Wire)
VERIFYING CELL FAN SPEED
The system will run the fans at full speed (approx. 3500 RPM). The Output from the controller to the Inverter is +10
VDC. The cell fans will slowly accelerate to full speed.
After the cell fans reach full speed, the true speed of the fans can be measured with a stroboscope. If one or more
fans are NOT between 3400-3600 RPM, then it is likely that either a fan motor or the fan motor wiring is faulty.
Содержание XPM3m
Страница 79: ...Technical Reference Manual XPM3m Revision Date August 2014 LIGHT TOWER Continued ...
Страница 90: ...Technical Reference Manual XPM3m Revision Date August 2014 ENHANCED COOLING PACKAGE EC 1 FLOW DIAGRAM ...
Страница 92: ...Technical Reference Manual XPM3m Revision Date August 2014 ENHANCED COOLING PACKAGE EC 2 FLOW DIAGRAM ...
Страница 94: ...Technical Reference Manual XPM3m Revision Date August 2014 ENHANCED COOLING PACKAGE EC 3 FLOW DIAGRAM ...