TWO ACTUATOR SYSTEM
The following initialization procedure applies to a two actuator system and requires two people to complete it:
1.
With the bonnet in the down position and the actuators properly connected mechanically and electrically,
raise the heat zone no more than 1
"
(25mm).
2.
Disconnect the power to the control box by shutting off the circuit breaker (F52) for at least 5 seconds.
3.
On the operator control panel, turn the Hood selector switch to the DOWN position and hold while
reconnecting the main power to the actuator control box. Listen for a buzzing sound coming from the control
box. At this point the hood selector switch will activate the LEFT actuator and lower the heat zone on that
side.
4.
Keep the hood selector switch engaged making sure the left actuator pulls the main heat zone down tightly
against the lower channel, then release the hood selector switch.
5.
Disconnect the power to the control box again by shutting off circuit breaker (F52) for at least 5 seconds
6.
On the operator control panel, and turn the hood selector switch to the UP position and hold while
reconnecting the main power to the actuator control box. Listen for a buzzing sound coming from the control
box. At this point, the hood selector switch has been used to activate the RIGHT actuator causing it to raise
the heat zone on that side. Once you notice the right side rising slightly, immediately turn the selector switch
to the DOWN position and lower the heat zone completely.
Caution:
Moving the heat zone any more than
the prescribed distance may cause structural damage to the system.
7.
Keep the hood selector switch engaged making sure the right actuator pulls the main heat zone down tight
against the lower channel, and then release the hood selector switch.
8.
Disconnect the power to the actuator control box again by shutting off circuit breaker (F52) for at least 5
seconds. The initialization process is now complete.
Содержание XPM3m
Страница 79: ...Technical Reference Manual XPM3m Revision Date August 2014 LIGHT TOWER Continued ...
Страница 90: ...Technical Reference Manual XPM3m Revision Date August 2014 ENHANCED COOLING PACKAGE EC 1 FLOW DIAGRAM ...
Страница 92: ...Technical Reference Manual XPM3m Revision Date August 2014 ENHANCED COOLING PACKAGE EC 2 FLOW DIAGRAM ...
Страница 94: ...Technical Reference Manual XPM3m Revision Date August 2014 ENHANCED COOLING PACKAGE EC 3 FLOW DIAGRAM ...