Technical Reference
Manual-XPM3m Revision Date: August 2014
XPM3m BASIC COOLING PACKAGE – EC1 OPTION
Description:
Standard on all machines
Performance Level:
Entry level
Cooling Medium:
Liquid
Warnings/Alarms:
Coolant Low Flow, Coolant High Pressure
Controls:
None
Facilities Impact:
Requires customer-supplied coolant (see Site Prep Manual for specification)
The upper cells in the cooling section are fitted with an internal tube type heat exchanger. Heat is
transferred from the recirculated gas to the coolant as the gas flows around the heat exchanger tubes. The heat is
then carried out of the tunnel via the customer-supplied coolant.
All upper cool cells are supplied with a hinged faceplate that is opened from the inside of the tunnel for ease
of maintenance. The tube type heat exchangers have valved quick disconnect couplings to prevent fluid loss during
removal for maintenance.
Cooling performance is dependent on the temperature of the customer-supplied coolant. It is an
uncontrolled system with only a thermocouple mounted in the top cells for temperature monitoring.