BATTERY BACK-UP FOR PC, CONTROLLER, CONVEYOR, AND HOOD LIFTS
The UPS Battery Back-up is:
Standard, (installed on all ovens
)
An option, (NOT installed on all ovens)
DESCRIPTION:
In case of a power failure, the UPS, (uninterruptable power supply) battery provides power to the PC, oven controller,
conveyor, and hood lift system. This provides a sufficient amount of time to completely empty out the Reflow Oven
of any product that may have been in process when the power failure occurred. The oven controller will provide an
audible alarm, and the PC will provide a message indicating the operation of the UPS system. The Battery Back-up
Option will also allow the Reflow Oven operator to open the Hoodlift should there be a need to remove product from
the oven due to the power failure.
NOTE
: The length of time the UPS will operate is dependent on oven size, not time. The UPS will operate for a
period of time equal to the amount of time it will take a PCB to travel the full length of the oven at the speed
contained in the running recipe at the time of the power failure. After this period, the UPS will turn off, shutting down
the PC, oven controller, conveyor, and hoodlift system.
(If the operator wishes to prevent the conveyor from running, the UPS backup battery should be disabled through
the Oven Control Program before a power failure.)
“POWER ON” DEFAULT FOR THE UPS BACKUP BATTERY:
Each time the oven’s PC is turned on or resets the UPS backup battery unit is reset to the previous status (on or off).
The oven software remembers the last configuration, even after being ‘reset'.
PLEASE READ THE UPS MANUFACTURERS MANUAL DELIVERED WITH THE OVEN
PRODUCT TRACKING AND ALARM
Product Tracking and Alarm is:
Standard, (installed on all ovens
)
An option, (NOT installed on all ovens)
The product tracking option has two photo-sensors. One mounted at the Onload end and one at the Offload
end of the oven. Boards loading onto the conveyor are detected by the sensor and counted. The program
calculates board travel through the oven, and each board is expected to pass under the Offload sensor within a time
period based on the conveyor speed (as measured in PPI) and the oven length.
If a board does not pass under the Offload sensor within the calculated time, the "Board Dropped Alarm" is activated.
The product length specified in the Product Definition determines the board length displayed on the screen.
Содержание XPM3m
Страница 79: ...Technical Reference Manual XPM3m Revision Date August 2014 LIGHT TOWER Continued ...
Страница 90: ...Technical Reference Manual XPM3m Revision Date August 2014 ENHANCED COOLING PACKAGE EC 1 FLOW DIAGRAM ...
Страница 92: ...Technical Reference Manual XPM3m Revision Date August 2014 ENHANCED COOLING PACKAGE EC 2 FLOW DIAGRAM ...
Страница 94: ...Technical Reference Manual XPM3m Revision Date August 2014 ENHANCED COOLING PACKAGE EC 3 FLOW DIAGRAM ...