background image

  

 

 
 

Operation and Maintenance Manual for   

ST35 Soldering System 

 

 
 

Manual 5050-0606 

Rev. Date 6/14/2022

 

 

 

 

This manual applies to:

 

 
 

Model 

Firmware 

Revision 

Required Power 

Part Number 

ST35 w/PS-90 Iron 

1-2 

120 VAC 

8007-0599 

ST35 w/PS-90 Iron 

1-2 

230 VAC 

8007-0600 

Содержание ST35 w/PS-90 Iron

Страница 1: ...e Manual for ST35 Soldering System Manual 5050 0606 Rev Date 6 14 2022 This manual applies to Model Firmware Revision Required Power Part Number ST35 w PS 90 Iron 1 2 120 VAC 8007 0599 ST35 w PS 90 Ir...

Страница 2: ...tion 3 Operation 4 Tip Offset 4 LED Display Normal Operation 4 Digital Control Indicator LED 4 Temperature Adjustment Display Mode 5 Default Factory Settings 5 Customizing Your System 5 Entering Set U...

Страница 3: ...t or exceed the requirements for electrostatic discharge set forth by ANSI ESD S20 20 Compliance with both standards is ensured by testing up to 50 MHz using the methodology described in ANSI ESD S13...

Страница 4: ...s 5 Exercise proper precautions when using chemicals e g solder paste or flux Refer to the Material Safety Data Sheet MSDS supplied with each chemical and adhere to all safety precautions recommended...

Страница 5: ...included hardware Assembly instructions are enclosed with each Tip Tool Stand Handpiece Connection The ST35 is designed to work with the SensaTemp PS 90 Soldering Iron or any other of the SensaTemp ha...

Страница 6: ...sting offset it is recommended to first check the actual temperature of the tip using a Tip Temperature Monitor To adjust the temperature offset hold the Program Key down for 5 seconds The display wil...

Страница 7: ...t Display Mode The display will show the following when adjusting the desired Set Tip Temperature 1 The Set Tip Temperature 2 HiL High Temperature Limit when adjusting the set tip temperature and the...

Страница 8: ...rs repeat steps 1 2 and enter the correct Password Once the LED Display reads P Choose one of the following options Press the Program Key to keep the current password even if there is no password and...

Страница 9: ...display of S 0 indicates that Setback is disabled Choose one of the following Press and release the Program Key to keep the currently stored Temperature Setback time Adjust the stored Temperature Setb...

Страница 10: ...ect handpiece and heater element replace as needed OSE Open Sensor Error Unit is unable to sense the sensor from the handpiece Make sure handpiece is connected Inspect handpiece and heater element for...

Страница 11: ...user s expense and risk User will be responsible for all costs of shipping equipment to Seller or other location for warranty service EXCEPT FOR THE REMEDY ABOVE DESCRIBED UNLESS OTHERWISE REQUIRED B...

Отзывы: