VITEK 5-in-1 CCTV TESTING MONITOR
VITEK 5-in-1 CCTV TESTING MONITOR
Page 47
Note:
1. Do not input power into the “DC12/3A OUTPUT” port.
2. Do not connect the DC12V/3A power to the DC12V/IN port of the IP camera tester to avoid
damage.
3. The IPC tester power output is close to 3A. If the IP camera’s power is over 3A, the tester will auto
enter protection mode. Disconnect all the connections of the tester and then connect the tester with
power adaptor to resume the tester.
4. Before turning on the PoE power output, please make sure the IP camera supports PoE power.
Otherwise it may damage the IP camera.
5 Make sure you plug in your IP camera to the LAN port prior to turning on PoE power.
6.
Make sure the tester is fully charged or more than 80% charged, otherwise the tester will show
“low power”, “not able to supply power”.
3.3.13 RJ45 cable TDR test
Connect cable to tester’s LAN port, click icon “ ” to enter RJ45 cable TDR test
app.
Single test:
Test cable status, length and attenuation.
Repeat test:
Continue to test cable status, length and attenuation.
Page 48
Status:
After linking up, the screen will display “online”, if not linked up or there is
an open circuit, the screen displays “open circuit”, if cable pair has a short circuit, the
screen displays “short circuit”.
Length:
The max test length is 180 meters. When cable is open circuit or short circuit,
test the cable length. If screen display is “online”, the testing result will be inaccurate.
Cable quality test:
Green is good quality cable, Yellow is Poor quality cable, Red is
wet cable. The attenuation value will be displayed when the cable is over 10 meters.
Advanced Test:
Test cable pair status, length, attenuation, reflectivity, impedance,
skew and other parameters.
Attenuation reflectivity:
After linking up, if the reflectivity value is 0, the best
quality communication is occurring
Impedance:
After linking up, if the impedance value is 100 Ω, the best quality
communication has been obtained. The range is generally 85-135 Ω.
Skew:
After 1000M link up, when skew value is 0ns, it is at the best quality
communication. If over 50ns, it will cause a Bit Error Rate in the transmission.
Click “Help”, check the instruction of all parameters.
3.3.14 Audio Recording
Connect an audio device to the IP tester’s audio input port. Click the icon to enter the Audio
Recorder app. Click the red button to stop, and the unit will prompt you to save the recording