For parametrization click in the
Project area
respectively in the
Device
overview
on the module you want to parameterize. The parameters of
the module appear in the Properties dialog. Here you can make your
parameter settings.
9.4 TIA Portal - Hardware configuration - Ethernet PG/OP channel
The CPU has an integrated Ethernet PG/OP channel. This channel
allows you to program and remote control your CPU.
n
The Ethernet PG/OP channel also gives you access to the internal
web page that contains information about firmware version, con-
nected I/O devices, current cycle times etc.
n
At the first commissioning respectively after a factory reset the
Ethernet PG/OP channel has no IP address.
n
For online access to the CPU via the Ethernet PG/OP channel,
valid IP address parameters have to be assigned to this. This is
called "initialization".
n
This can be done with the Siemens TIA Portal.
Parametrization
Overview
VIPA System 300S CPU
Configuration with TIA Portal
TIA Portal - Hardware configuration - Ethernet PG/OP channel
HB140 | CPU | 315-2AG13 | GB | Rev. 14-40