Chapter 4 Deployment CPU 313SC/DPM
Manual VIPA System 300S SPEED7
4-32
HB140E - CPU SC - RE_313-6CF03 - Rev. 07/45
The CPU 313SC/DPM has an integrated web page that monitors
information about firmware version of the I/O components. The Ethernet
PG/OP channel provides the access to this web page.
To activate the PG/OP channel you have to enter according IP parameters.
This can be made in Siemens SIMATIC manager either by a hardware
configuration, loaded by MMC respectively MPI or via Ethernet by means of
the MAC address with
PLC
>
Assign Ethernet Address
.
After that you may access the PG/OP channel with a web browser via the
IP address of the project engineering. More detailed information is to find in
"Access to Ethernet PG/OP channel and website".
First establish an online connection to the CPU. To monitor the module
information you choose the option
PLC
>
Module Information
in the
Siemens SIMATIC Manager. Via the register "General" the window with
hardware and firmware version may be selected.
From software-technical reasons there is something different of the
CPU 313SC/DPM to the CPU 313C-2DP from Siemens:
The releases of hard and software may be found at "Order
No./Description". Here the number at "Version" is irrelevant.
Order No./Description
Component
Version
6ES7 313-6CF03
Hardware
1
VIPA AG01 10V3.2.8
Firmware
V2.0.0
Description:
Name:
Version:
CPU 313C-2DP
CPU 313C-2DP
System identification: SIMATIC 300
irrelevant
Hardware:
Release
Sub version
Firmware:
Version
Note!
Every register of the module information dialog is supported by the VIPA
CPUs. More about these registers may be found in the online help of the
Siemens SIMATIC manager.
Display the
Firmware version of
the SPEED7 system
via web page
Determine CPU
firmware version
with module
information
Содержание 313-6CF03
Страница 2: ...Lerrzeichen ...
Страница 40: ...Chapter 3 Hardware description Manual VIPA System 300S SPEED7 3 14 HB140E CPU SC RE_313 6CF03 Rev 07 45 ...
Страница 122: ...Chapter 5 Deployment I O periphery Manual VIPA System 300S SPEED7 5 36 HB140E CPU SC RE_313 6CF03 Rev 07 45 ...
Страница 140: ...Chapter 6 Deployment PtP communication Manual VIPA System 300S SPEED7 6 18 HB140E CPU SC RE_313 6CF03 Rev 07 45 ...