Manual VIPA System 300S SPEED7
Chapter 4 Deployment CPU 313SC/DPM
HB140E - CPU SC - RE_313-6CF03 - Rev. 07/45
4-15
The CPU does not evaluate all parameters that may be set at the hardware
configuration.
The following parameters are supported at this time:
Since the CPU 313SC/DPM is configured as CPU 313C-2DP from
Siemens, here the short description CPU 313C-2DP stands.
Order number and firmware are identical to the details in the "Hardware
catalog" window.
The
Name
field provides a short description of the module, which you can
change to meet your requirements. If you change the description, the new
description appears in the SIMATIC Manager.
Here the address of the MPI interface stands.
Click the "Properties" button to change the properties of the MPI interface.
In this field information about the module may be entered.
If the checkbox for "Startup when expected/actual configuration differ" is
deselected
and at least one module is not located at its configured slot or if
another type of module is inserted there instead, then the CPU switches to
STOP mode.
If the checkbox for "Startup when expected/actual configuration differ" is
selected
, then the CPU starts even if there are modules are not located in
their configured slots of if another type of module is inserted there instead,
such as during an initial system start-up.
This operation specifies the maximum time for the ready message of all
configured modules after PowerON. If the modules do not send a ready
message to the CPU by the time the monitoring time has expired, the
actual configuration becomes unequal to the preset configuration.
The maximum time for the transfer of parameters to parameterizable
modules. If not all of the modules have been assigned parameters by the
time this monitoring time has expired, the actual configuration becomes
unequal to the preset configuration.
Supported
parameters
General
Short description
Order No. /
Firmware
Name
Interface
Properties
Comment
Startup
Startup when
expected/actual
configuration differ
Monitoring Time for
Ready message by
modules [100ms]
Monitoring Time for
Transfer of
parameters to
modules [100ms]