2.3 Installation (continued)
2.3.3 Connect Exit Buttons and Door Open/Close Sensors
All Exit button inputs are
ACTIVE LOW
, i.e. connect to GND(0V) to unlock the door.
All Door open/close sensors inputs are also
ACTIVE LOW
, i.e. when a door is closed, the voltage on the corresponding
SR input (SR1, SR2… ) should become GND(0V). If the door is opened, the corresponding SR input should be open
circuit (No connection).