VIP Vision Access Control Installation Guide - Version: VIPACC-Q219.1
32
3.2 Smart PSS Installation (continued)
3.2.12 Configure Doors
1. Click the Console icon.
2.
Choose the door to be configured by right clicking the door name and clicking Door Configuration.
3. Enter all user information in the box.
Door:
Name of the door
Reader1:
Name of the entrance reader
Reader2:
Name of the exit reader
Status:
Normal, Always Open, Always Close
Unlock hold interval:
The time that the relay stays unlocked.
Close Timeout:
The timeout period if a door is leave opened
before alarm is triggered.
Door Open/Close status switch must be connected for Intrusion
and Overtime alarms to work.
If the alarm is triggered, the Access Control console will display the alarm event time and change the icon on the door.
Содержание ACCON Series
Страница 11: ...Visit www vip vision com for full user manual and support 11 2 2 Wiring Diagrams continued ACCON 2P41...
Страница 12: ...VIP Vision Access Control Installation Guide Version VIPACC Q219 1 12 2 2 Wiring Diagrams continued ACCON 2P42...
Страница 13: ...Visit www vip vision com for full user manual and support 13 2 2 Wiring Diagrams continued ACCON 2P81...