2.3.6 Connect External Alarm Outputs (optional)
If any one of the external alarm inputs are triggered, the corresponding output relay will stay on for 15 seconds.
The following tables are for
2P42 and 2P81 ONLY
For 2P42, two External Alarm inputs share one set of External Alarm output relay.
For 2P8, each External Alarm input has one External Alarm output relay.
ACCON-2P42
ACCON-2P81
External Alarm Input
Relay
External Alarm Output
Terminal Block CON10
ALARM1
JK1
OUT1+, OUT1- (Pin 1-2)
ALARM2
ALARM3
JK2
OUT2+, OUT2- (Pin 3-4)
ALARM4
ALARM5
JK3
OUT3+, OUT3- (Pin 5-6)
ALARM6
ALARM7
JK4
OUT4+, OUT4- (Pin 7-8)
ALARM8
External Alarm Input
Relay
External Alarm Output
Terminal Block CON10
ALARM1
JK1
OUT1+, OUT1- (Pin 1-2)
ALARM2
JK2
OUT2+, OUT2- (Pin 3-4)
ALARM3
JK3
OUT3+, OUT3- (Pin 5-6)
ALARM4
JK4
OUT4+, OUT4- (Pin 7-8)