Operation of Controls

Adjust to desired

speed.

Blower Speed

Adjust to desired

speed.

Adjust to desired

mode position 

(DASH position 

recommended).

Adjust to desired

speed.

Adjust to DEFROST position for maximum defrost, or 

between FLOOR and DEFROST positions for a bi-level 

blend (Compressor is automatically engaged).

Adjust to desired 

temperature.

For A/C operation, adjust to

coldest position to engage 

compressor (Adjust between 

HOT and COLD to reach

desired temperature).

A/C Operation

Heat Operation

Defrost/De-fog Operation

On Gen IV systems with three lever/knob controls, the temperature control toggles between heat and A/C 

operations. To activate A/C, move the temperature lever/knob all the way to cold and then back it off to the desired 

vent temperature. For heat operation, move the temperature lever/knob all the way to hot and then adjust to the 

desired vent temperature. The blower will momentarily change speed, each time you toggle between operations, to 

indicate the change. 

NOTE: For proper control panel function, refer to control panel instructions for 

calibration procedure.

Blower Speed

Blower Speed

This lever/knob controls

blower speed, from 

OFF to HI.

This lever/knob controls 

the mode positions,

from DASH to FLOOR

to DEFROST, with a 

blend in between.

This lever/knob controls

the temperature,

from HOT to COLD.

Blower Speed

Mode Control

Temperature Control

Blower 

Speed 

Temperature

Control

Mode

Control

Temperature Control

Temperature Control

Temperature Control

Mode Control

Mode Control

Mode Control

For maximum heating, adjust 

to hottest position (Adjust 

between HOT and COLD to 

reach desired temperature).

Adjust to desired

mode position

(FLOOR position 

recommended).

DASH

DASH

DASH

HOT

HOT

HOT

HI

HI

HI

DASH

HOT

HI

Содержание 1967-68 CAMARO w/o Factory Air Gen IV

Страница 1: ...gistered Company 1967 68 Chevrolet Camaro without Factory Air Control Panel Conversion Kit 475168 18865 Goll St San Antonio TX 78266 Phone 210 654 7171 Fax 210 654 3113 www vintageair com 905168 REV G...

Страница 2: ...Cold Hot Control Harness Cold Hot Control Harness Cont Off Hi Cable Converter Assembly Installation Off Hi Control Harness Final Steps Control Panel Calibration Procedure Control Panel Calibration Pr...

Страница 3: ...Head Label Backing 1 2 3 4 5 6 7 8 9 1 3 1 3 3 5 1 4 1 484168 112002 SUA 232002 VUA 65976 VUE 491010 VUR 21301 VUP 231520 18235 VUB 484170 Packing List 475168 4 5 6 7 8 9 2 3 Before beginning installa...

Страница 4: ...the replacement placard mode label that comes with this kit To use the replacement placard mode label you must modify parts of the control panel assembly as described below We leave it up to you the...

Страница 5: ...OEM light baffle discard Install OEM backing plate placard and control panel face plate Secure control panel face plate to control panel using 4 8 x 1 2 pan head screws Reinstall knobs DASH HOT DEFROS...

Страница 6: ...Figure 5 below Cable Converter Assembly Mounting Clamp Installation 1 Cut at Each Side of Hole as Shown Off Hi Lever Cut at 2nd Hole Remove Shaded Portion Cold Hot Lever Cut at 6th Hole Remove Shaded...

Страница 7: ...position the cable converter assembly such that the flat part of the rod is as close to flush as possible with the end of the housing at the lever s innermost position See Figure 6 below Secure the c...

Страница 8: ...cated between the end of the wire jacket and the step in the cable converter housing forcing a bend in each wire as it passes over the step in the cable converter housing The head of the tie wrap must...

Страница 9: ...ition the cable converter assembly such that the flat part of the rod is as close to flush as possible with the end of the housing at the lever s innermost position Secure the cable converter lever pu...

Страница 10: ...nto the OEM cable mounting stud using a 3 16 push on ring as shown in Figure 12 below Off Hi Cable Converter Assembly Installation 1 2 3 4 5 Cold Hot Control Harness Cont Once the wires are correctly...

Страница 11: ...re jacket and the step in the cable converter housing forcing a bend in each wire as it passes over the step in the cable converter housing The head of the tie wrap must fall on the edge of the housin...

Страница 12: ...alibration procedure and operation instructions A Calibrating the control panel will set the range of travel for the cable converters connected to the OEM control panel levers Performing this procedur...

Страница 13: ...ground jumper wire to a suitable chassis ground This jumper wire must be easily connected to the gray programming wire located in the main Gen IV wiring harness next to the relays During the calibrati...

Страница 14: ...seconds 4 Move the control levers knobs to the positions shown 5 Disconnect the white jumper wire from the gray program wire The blower speed will change indicating completion of the calibration proc...

Страница 15: ...VUA CIRCUIT BREAKER 30 AMP WIDE OPEN THROTTLE SWITCH OPTIONAL DASH LAMP IF USED Dash Lamp Is Used Only With Type 232007 VUR Harness Warning Always Mount Circuit Breaker As Close to the Battery As Pos...

Страница 16: ...ired vent temperature For heat operation move the temperature lever knob all the way to hot and then adjust to the desired vent temperature The blower will momentarily change speed each time you toggl...

Страница 17: ......

Страница 18: ...16 Clamp Cable Converter Tie Wrap 4 Ground Wire Screw 8 x 1 2 Pan Head Label Backing 1 2 3 4 5 6 7 8 9 1 3 1 3 3 5 1 4 1 484168 112002 SUA 232002 VUA 65976 VUE 491010 VUR 21301 VUP 231520 18235 VUB 48...

Отзывы: