background image

10

www.vintageair.com

905168 REV G 4/13/15, PG 10 OF 17

Install the cable converter assembly onto the Off/Hi lever.
Install the cable converter push rod onto the OEM cable mounting stud on the lever.
Secure the cable converter assembly onto the OEM control panel using the OEM screw in the OEM cable clamp 

mounting location (See Figure 12, below).
Since the cable converter assembly can slide back and forth in the clamp before the screw is tightened, position 

the cable converter assembly such that the flat part of the rod is as close to flush as possible with the end of 

the housing at the lever’s innermost position.
Secure the cable converter lever push rod onto the OEM cable mounting stud using a 3/16” push-on ring as 

shown in Figure 12, below.

Off/Hi Cable Converter Assembly 

Installation

1.
2.
3.

4.

5.

Cold/Hot Control Harness (Cont.)

Once the wires are correctly plugged into the cable converter assembly, secure the wires to the cable converter 

assembly using the supplied tie wraps. The tie wrap must be located between the end of the wire jacket and 

the step in the cable converter housing, forcing a bend in each wire as it passes over the step in the cable 

converter housing. The head of the tie wrap must fall on the edge of the housing to remain tight. Ensure that 

the tie wraps are tight enough that the wires cannot move (See Figure 11, below).

1.

Force Bend

in Wires

Over Step

Step in

Cable Converter

Housing

Cable Converter

Clamp

Cable Converter

Assembly

Tie Wrap

Tie Wrap

Wire 

Jacket

Wire 

Jacket

Figure 11

Figure 12

Содержание 1967-68 CAMARO w/o Factory Air Gen IV

Страница 1: ...gistered Company 1967 68 Chevrolet Camaro without Factory Air Control Panel Conversion Kit 475168 18865 Goll St San Antonio TX 78266 Phone 210 654 7171 Fax 210 654 3113 www vintageair com 905168 REV G...

Страница 2: ...Cold Hot Control Harness Cold Hot Control Harness Cont Off Hi Cable Converter Assembly Installation Off Hi Control Harness Final Steps Control Panel Calibration Procedure Control Panel Calibration Pr...

Страница 3: ...Head Label Backing 1 2 3 4 5 6 7 8 9 1 3 1 3 3 5 1 4 1 484168 112002 SUA 232002 VUA 65976 VUE 491010 VUR 21301 VUP 231520 18235 VUB 484170 Packing List 475168 4 5 6 7 8 9 2 3 Before beginning installa...

Страница 4: ...the replacement placard mode label that comes with this kit To use the replacement placard mode label you must modify parts of the control panel assembly as described below We leave it up to you the...

Страница 5: ...OEM light baffle discard Install OEM backing plate placard and control panel face plate Secure control panel face plate to control panel using 4 8 x 1 2 pan head screws Reinstall knobs DASH HOT DEFROS...

Страница 6: ...Figure 5 below Cable Converter Assembly Mounting Clamp Installation 1 Cut at Each Side of Hole as Shown Off Hi Lever Cut at 2nd Hole Remove Shaded Portion Cold Hot Lever Cut at 6th Hole Remove Shaded...

Страница 7: ...position the cable converter assembly such that the flat part of the rod is as close to flush as possible with the end of the housing at the lever s innermost position See Figure 6 below Secure the c...

Страница 8: ...cated between the end of the wire jacket and the step in the cable converter housing forcing a bend in each wire as it passes over the step in the cable converter housing The head of the tie wrap must...

Страница 9: ...ition the cable converter assembly such that the flat part of the rod is as close to flush as possible with the end of the housing at the lever s innermost position Secure the cable converter lever pu...

Страница 10: ...nto the OEM cable mounting stud using a 3 16 push on ring as shown in Figure 12 below Off Hi Cable Converter Assembly Installation 1 2 3 4 5 Cold Hot Control Harness Cont Once the wires are correctly...

Страница 11: ...re jacket and the step in the cable converter housing forcing a bend in each wire as it passes over the step in the cable converter housing The head of the tie wrap must fall on the edge of the housin...

Страница 12: ...alibration procedure and operation instructions A Calibrating the control panel will set the range of travel for the cable converters connected to the OEM control panel levers Performing this procedur...

Страница 13: ...ground jumper wire to a suitable chassis ground This jumper wire must be easily connected to the gray programming wire located in the main Gen IV wiring harness next to the relays During the calibrati...

Страница 14: ...seconds 4 Move the control levers knobs to the positions shown 5 Disconnect the white jumper wire from the gray program wire The blower speed will change indicating completion of the calibration proc...

Страница 15: ...VUA CIRCUIT BREAKER 30 AMP WIDE OPEN THROTTLE SWITCH OPTIONAL DASH LAMP IF USED Dash Lamp Is Used Only With Type 232007 VUR Harness Warning Always Mount Circuit Breaker As Close to the Battery As Pos...

Страница 16: ...ired vent temperature For heat operation move the temperature lever knob all the way to hot and then adjust to the desired vent temperature The blower will momentarily change speed each time you toggl...

Страница 17: ......

Страница 18: ...16 Clamp Cable Converter Tie Wrap 4 Ground Wire Screw 8 x 1 2 Pan Head Label Backing 1 2 3 4 5 6 7 8 9 1 3 1 3 3 5 1 4 1 484168 112002 SUA 232002 VUA 65976 VUE 491010 VUR 21301 VUP 231520 18235 VUB 48...

Отзывы: