ENGLISH - 5
• red/green two-colour LED blinking:
- it blinks for a few seconds after the phase of resetting the device.
Settings (programmable via the control panel)
1) Zone: the assignment zone from 1 to 30, set from the control
panel by selecting the number of the chosen zone in the spe-
cific menu; the interface can be configured in zone 31 when
you need the “PANIC” button of the remote control 01819 to
activate the audible panic alarm (see page 6).
2) Sensitivity of the antitamper device: (default 0 that is disabled).
Value that adjusts the sensitivity of the optical antitamper in
the radio interface. Adjustment range from 0 (disabled) to 15
(maximum sensitivity);
3) Supervised (default OFF). Supervision of the Radio Frequency
detectors on (ON) or off (OFF);
4) Activation delay zones from 1 to 10: 0 s = instantaneous. It can
be increased up to 60 s in steps of 1 s;
5) Activation delay zones from 10 to 20: 0 s = instantaneous. It can
be increased up to 60 s in steps of 1 s;
6) Activation delay zones from 20 to 30: 0 s = instantaneous. It can
be increased up to 60 s in steps of 1 s.
Note
: If a radio frequency detector for alarms of a technical type
(water detector, for instance) is configured in the same zone as a
relay actuator (one-position stable), this will switch over when the
detector signals the alarm.
Standard compliance
R&TTE directive
Standards EN 60065, EN 50130-4, EN 61000-6-3, EN 301489-1,
EN 301489-3, EN 300220-2.
Содержание Arke 19493
Страница 2: ......
Страница 12: ...10 ENGLISH Connections 1 2 3 4 6LR61 9V 1 2 3 4 Connection example N C contact...
Страница 19: ...ENGLISH 17 Connections 1 2 3 4 6LR61 9V 1 2 3 4 N C contact...
Страница 31: ...ENGLISH 29 Connections Trimmer for adjusting the loudness of the beeps Battery pack connector...
Страница 36: ......
Страница 37: ......