ENGLISH - 31
Operation
• Audible alarm governed by the control panel lasting 3 min.
for each alarm cycle.
• Alarm signalling delay equal to approx. 12 s with audible
pre-alarm warnings (beeps).
• Audible warning to confirm the system is on (1 beep), off
(2 beeps) and partitioned (3 beeps). The volume of this
audible warning is adjustable with the special trimmer (see
figure page 29).
• Extended audible warning when putting out of service for
maintenance; set the control panel on Walktest before
opening the siren.
• Successful configuration signal (6 beeps and flashes).
• Siren enclosure protection contacts closing signal (1
beep).
• Approximately every 30 minutes, the siren sends a
correctly operating signal to the control panel (via radio
interface).
• Anti-sabotage protection: Opening the siren enclosure
causes the tamper alarm;
before changing the batte-
ry pack it is necessary to set the control panel on
Walktest
.
• Walktest: In this phase, the control panel identifies the type
of detector and provides an indication on the level of radio
reception.
• Flat battery warning with signal on control panel.