14 - ENGLISH
- If the N/C contact is used too, prepare the control panel
for configuration (the detector connected to the N/C contact
can also be assigned to a different zone to that of the infra-
red sensor) and then put dip-switch 2 onto ON; the control
panel will display configuration of the device.
Warning
Connect the N/C contact detectors as illustrated in the figure on
page 10. Using fast contacts such as those for roller shutters
and/or inertia sensors, put dip-switch 3 onto ON; in this case the
alarm will be signalled if, within 30 s, there are 6 quick openings
of the contact.
N.B
: The N/C terminal block is self-learning; it is then neces-
sary for it to remain closed for at least 6 s.
Important
:
Bevor er einsatzbereit ist, braucht der Melder nach
Einlegen der Batterie eine gewisse Zeit zur Stabilisierung (rote Led
leuchtet etwa 30 Sekunden lang mit Dauerlicht).
- Put the dip-switches 1,3 and 4 onto the desired position and
leave 2 OFF (the dip-switches must be positioned before
inserting the battery).
- If used, make the connections to the N/C input.
- Prepare the control panel for configuring the radio-frequency
detector then insert the battery into the device; the control
panel will confirm reception of the message.
The display will show a configuration message.
9 Volt
6LR61
Содержание Arke 19493
Страница 2: ......
Страница 12: ...10 ENGLISH Connections 1 2 3 4 6LR61 9V 1 2 3 4 Connection example N C contact...
Страница 19: ...ENGLISH 17 Connections 1 2 3 4 6LR61 9V 1 2 3 4 N C contact...
Страница 31: ...ENGLISH 29 Connections Trimmer for adjusting the loudness of the beeps Battery pack connector...
Страница 36: ......
Страница 37: ......