98
Permissible ambient temperature
■ during operation:
0 to +40 °C
■ during storage and
transport:
-20 to +65 °C
Control thermostat
and temperature con-
troller setting:
75 °C
Line fuse (mains):
max. 16 A
Rated breaking capacity of relay out-
puts at 230 V~ for
■ Heating circuit
pump
sÖ
:
2 (1) A~
*4
■ Circulation pump
sA
:
2 (1) A~
*4
■ DHW circulation
pump
sK
:
2 (1) A~
*4
■ Central fault mes-
sage
gÖ
:
0.4 (0.2) A~
*4
Oil condensing boiler, type B
23
, C
33x
, C
53x
, C
63x
Rated output
kW
12.9/19.3
16.1/23.5
19.3/28.9
Burner stage
1
2
1
2
1
2
Rated output
kW
12.9
19.3
16.1
23.5
19.3
28.9
Power consumption
W
152
220
169
240
170
270
Motor speed
Oil pump drive
min
-1
2880
2880
2880
Capacity
Oil pump
l/h
45
45
45
Burner version
Two-stage
Two-stage
Two-stage
Product ID
_
-0035 BS 104
*4
Total: max. 4 A~
Specification
Specification
5692 774 GB
Содержание Vitoladens 300-C
Страница 88: ...88 Internal extensions H1 PCB A5 and H3 PCB A9 Designs Connection and wiring diagram internal cont 5692 774 GB ...
Страница 92: ...92 206 217 221 205 202 203 204 221 201 214 208 216 215 200 214 Parts lists Parts lists cont 5692 774 GB ...
Страница 95: ...95 308 312 311 310 313 309 306 307 305 309 314 304 Parts lists Parts lists cont 5692 774 GB ...
Страница 96: ...96 100 102 108 111 112 103 109 106 101 Parts lists Parts lists cont 5692 774 GB ...
Страница 103: ...103 5692 774 GB ...