20
4.
Secure Allen screw
C
of the rifling
facility. Check nozzle gap "a".
!
Please note
An incorrectly adjusted nozzle
gap "a" can result in irregular
operation of the burner and
even a fault shutdown.
Rated output
kW
12.9/19.3
16.1/23.5
19.3/28.9
Nozzle gap "a"
(see page 19)
mm
3.0
+0.2/-0.3
1.5
+0.2/-0.3
1.5
+0.2/-0.3
Burner installation
Tighten screws/bolts across and click
cables back into place.
Cleaning and replacing the oil pump filter, if required
Danfoss oil pump, type BFP 52
A
B
C
A
Filter plug
B
O-ring (replace)
C
Filter (replace)
Commissioning, inspection, maintenance
Further details regarding the individual steps