12
Yes
Fan starts after no
more than
10 min.
Green LED on
ignition trans-
former flashes.
No
Fault
Check the oil pre-
heater, fan, cables
and plug-in con-
nectors
(the oil preheater
has not switched
through; the tem-
perature is not ach-
ieved)
F9
Yes
The air pressure
switch responds
No
after approx. 51 s
Check the air pres-
sure switch, cables
and plug-in con-
nectors
Fault
F5
Yes
Ignition and oil
pump motor start
No
Check the ignition
module and oil
pump motor,
cables and plug-in
connectors
Yes
The solenoid
valves open
No
Fault
Check the oil sup-
ply; check the sol-
enoid valves
F4
Yes
Flame signal
present
Symbol
A
No
Fault
Check ignition
electrodes, elec-
trode gaps and
connecting lines
F4
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5692 774 GB
Содержание Vitoladens 300-C
Страница 88: ...88 Internal extensions H1 PCB A5 and H3 PCB A9 Designs Connection and wiring diagram internal cont 5692 774 GB ...
Страница 92: ...92 206 217 221 205 202 203 204 221 201 214 208 216 215 200 214 Parts lists Parts lists cont 5692 774 GB ...
Страница 95: ...95 308 312 311 310 313 309 306 307 305 309 314 304 Parts lists Parts lists cont 5692 774 GB ...
Страница 96: ...96 100 102 108 111 112 103 109 106 101 Parts lists Parts lists cont 5692 774 GB ...
Страница 103: ...103 5692 774 GB ...