30
System version 3
One heating circuit without mixer A1 and one heating circuit with mixer M2 with
system separation (with/without DHW heating)
M
1
Vitoladens 300-C
2
Circulation pump for cylinder heat-
ing
3
DHW cylinder
4
Cylinder temperature sensor
5
DHW circulation pump
6
Outside temperature sensor
7
Heating circuit without mixer A1
8
Heating circuit pump A1
9
Heating circuit with mixer M2
qP
Temperature limiter for limiting the
maximum temperature of underfloor
heating systems
Flow temperature sensor M2
qW
Heating circuit pump M2
qE
Heat exchanger for system separa-
tion
qR
Heating circuit pump M2
qT
Extension kit for one heating circuit
with mixer M2
Adjusting the heating curves
The heating curves illustrate the relation-
ship between the outside temperature
and the boiler water or flow tempera-
ture.
To put it simply: The lower the outside
temperature, the higher the boiler water
or flow temperature.
The room temperature, again, depends
on the boiler water or the flow tempera-
ture.
Settings in the delivered condition:
■ Slope = 1.4
■ Level = 0
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5692 774 GB
Содержание Vitoladens 300-C
Страница 88: ...88 Internal extensions H1 PCB A5 and H3 PCB A9 Designs Connection and wiring diagram internal cont 5692 774 GB ...
Страница 92: ...92 206 217 221 205 202 203 204 221 201 214 208 216 215 200 214 Parts lists Parts lists cont 5692 774 GB ...
Страница 95: ...95 308 312 311 310 313 309 306 307 305 309 314 304 Parts lists Parts lists cont 5692 774 GB ...
Страница 96: ...96 100 102 108 111 112 103 109 106 101 Parts lists Parts lists cont 5692 774 GB ...
Страница 103: ...103 5692 774 GB ...