Replacing third party boilers with the Vitodens 200-W
Using an adaptor, the Vitodens hydraulic connections are compatible
with Ceramini-Z-SR, Cerastar-ZR/-ZWR and Thermoblock-VC110E-/
VC112E/-VC/-VCW boilers.
For modernisation projects, adaptors are available as accessories
(see pricelist). These comprise connection components for the heat-
ing water and DHW sides and fixings for replacing the third party
appliances listed below with a Vitodens. A pre-plumbing jig for sur-
face mounting or valves/fittings for surface mounting must be
ordered separately in addition to the Vitodens 200-W.
The installation work involved is no greater than replacement with a
same-brand appliance.
Where a wall mounted gas boiler is replaced by a Vitodens 200-W
gas condensing system boiler, the flue must also be replaced with a
system that is suitable for "condensing operation" (see pricelist "Flue
systems for the Vitodens").
Adapt the flue connections on site.
Note
For modernisation projects, the State Building Regulations [Ger-
many] require the on-site installation of a gas shut-off valve with
thermally activated shut-off facility.
Replacing a Ceramini-Z-SR with a Vitodens 200-W, 11 and 19 kW
55
890
Ceramini
102
770
992
260
Ø 90
A
B
a
189
Vitodens
960
770
1062
102
Ceramini
Ø 90
260
b
A
Open flue operation
B
Room sealed operation
Dim.
Flush mounting
Surface mounting
a
mm
790
+25/-0
802
+50/-0
Note
Height of flue gas connection in combination with balanced flue bend
60/100. If using a balanced flue inspection bend 60/100, the height is
reduced by 10 mm.
Design information
(cont.)
VITODENS
VIESMANN
105
5853906
8
Содержание Vitodens 200-W B2HE
Страница 154: ...154 VIESMANN VITODENS...