Specification, room temperature controller
Rated voltage
3 V–
Transmission frequency
868 MHz
Transmission
< 10 mW
Range
approx. 25 to 30 m inside buildings,
subject to construction
IP rating
IP 20 to EN 60529
Ensure through design/installation
Function type
RS type 1B to EN 60730-1
Permissible ambient temperature
– Operation
0 to +40 °C
– Storage and transport
–25 to +65 °C
Setting range
– Comfort temperature
10 to 40 °C
– Setback temperature
10 to 40 °C
– Frost protection temper-
ature
5 °C
Power reserve during bat-
tery change
3 min
Specification, receiver
Operating voltage
230 V~± 10 % 50 Hz
Rated breaking capacity of the floating contact
– max.
6(1) A, 230 V~
– min.
1 mA, 5 V–
IP rating
IP 20 to EN 60529
Ensure through design/installation
Safety category
II to EN 60730-1 subject to correct in-
stallation
Permissible ambient temperature
– Operation
0 to +40 °C
– Storage and transport
–25 to +65 °C
Vitotrol 200-E
Part no. Z017415
■ PlusBus subscriber
■ Max. 2 Vitotrol 200-E can be connected to a heat generator control
as a PlusBus subscriber.
■ Up to 4 heating circuits can be controlled with a Vitotrol 200-E.
Alternatively, a Vitotrol 200-E can be assigned to a heating circuit.
A heating circuit cannot be controlled by more than one remote
control.
Displays
■ Room temperature
■ Outside temperature
■ Operating condition
Settings
■ Set room temperature for standard room temperature, comfort
room temperature and reduced room temperature
■ Set DHW temperature
■ Switching times for heating circuits and DHW heating, plus further
settings via plain text menu on the display
■ Integral room temperature sensor for room temperature hook-up
(only for one heating circuit with mixer)
Quick select function for:
■ Comfort mode
■ One-off cylinder heat-up
■ Holiday program
■ "Holiday at home"
Installation location
■ Weather-compensated operation:
Installation anywhere in the building
■ Room temperature hook-up:
The integral room temperature sensor captures the room tempera-
ture and effects any necessary correction of the flow temperature.
The captured room temperature depends on the installation site:
– Installation only in enclosed buildings
– Not next to windows or doors
– Not between shelves, in recesses, etc.
– Not near heat sources (direct insolation, fireplace, TV set, etc.)
Connection
■ 2-core lead, length max. 50 m (even if connecting several remote
control units)
■ Never route this cable immediately next to 230/400 V cables.
■ Extra low voltage (ELV) plug included in standard delivery
Specification
20,5
155
97
Vitotrol 200-E
Power supply
Via PlusBus
Voltage
V
28
Current
mA
25
Protection class
Permissible ambient tempera-
ture
– Operation
°C
0 to +40
– Storage and transport
°C
–20 to +65 °C
Control unit
(cont.)
VITODENS
VIESMANN
143
5853906
9