■ Display of:
– Outside temperature
– Heat generator flow temperature
– Flow temperature in heating circuits with mixer
– DHW temperature
– Operating data
– Diagnostic details
– Fault messages
■ Available languages:
– German
– Czech
– Danish
– English
– French
– Italian
– Dutch
– Polish
– Slovak
– Swedish
– Estonian
– Croatian
– Latvian
– Lithuanian
– Bulgarian
– Romanian
– Russian
– Slovenian
– Spanish
– Turkish
– Hungarian
Functions
Control unit with 7-inch screen
■ Control of the flow temperature (selectable):
– Weather-compensated
– Constant
– Room temperature-dependent
■ Control of 1 heating circuit without mixer
■ Control of max. 2 heating circuits with mixer (accessories)
■ Electronic maximum and minimum temperature limit
■ Demand-dependent heating circuit pump and burner shutdown
control
■ Variable heating limit setting
■ Automatic winter/summertime changeover
■ Individually programmable switching times for central heating and
DHW heating.
Max. 4 time phases for each per day
■ Heating system frost protection monitoring
■ Integral diagnostic system
■ Service indicator
■ Commissioning via commissioning assistant
■ Cylinder temperature controller with priority control
■ Hygiene function for DHW heating (short-term heating to a higher
temperature)
■ In conjunction with the EM-S1 extension module (only for
Vitodens 200-W and 242-F):
– Control of solar DHW heating
Or
– Central heating backup with combi cylinder
Note
■ Simultaneous screed drying program for all heating circuits (choice
of 6 stored programs)
■ Connection option for extension modules
Control unit with 3.5-inch screen
■ Control of the flow temperature (selectable):
– Weather-compensated
– Constant
– Room temperature-dependent
■ Control of 1 heating circuit without mixer
■ Control of max. 2 heating circuits with mixer (accessories)
■ Electronic maximum and minimum temperature limit
■ Demand-dependent heating circuit pump and burner shutdown
control
■ Variable heating limit setting
■ Automatic winter/summertime changeover
■ Individually programmable switching times for central heating and
DHW heating.
Max. 4 time phases for each per day
■ Heating system frost protection monitoring
■ Integral diagnostic system
■ Service indicator
■ Commissioning via commissioning assistant
■ Cylinder temperature controller with priority control
■ Hygiene function for DHW heating (short-term heating to a higher
temperature)
■ In conjunction with the EM-S1 extension module (only for
Vitodens 200-W and 242-F):
– Control of solar DHW heating
Or
– Central heating backup with combi cylinder
Note
■ Simultaneous screed drying program for all heating circuits (choice
of 6 stored programs)
■ Connection option for extension modules
To reduce the heat-up output, the reduced room temperature can be
raised when outside temperatures are low. To shorten the heat-up
time after a setback phase the flow temperature is raised for a limi-
ted time.
According to the [German] Energy Saving Ordinance, the tempera-
ture in each room must be individually controlled, e.g. by means of
thermostatic valves.
Control unit
(cont.)
VITODENS
VIESMANN
139
5853906
9