Gas boiler, type B and C, category II
2N3P
Type
B2KE
Rated heating output range (details to EN 15502)
T
F
/T
R
= 50/30 °C
Natural gas
kW
1.9 - 19.0
1.9 - 25.0
1.9 - 32.0
LPG
kW
2.5 - 19.0
2.5 - 25.0
2.5 - 32.0
T
F
/T
R
= 80/60 °C
Natural gas
kW
1.7 - 17.4
1.7 - 22.9
1.7 - 29.3
LPG
kW
2.2 - 17.4
2.2 - 22.9
2.2 - 29.3
LPG
mbar
kPa
57.5
5.75
57.5
5.75
57.5
5.75
Sound power level
(to EN ISO 15036-1)
At partial load
dB(A)
27
27
27
At rated heating output (DHW heating)
dB(A)
41
42
47
Power consumption
(in the delivered condition)
W
47
68
92
Weight
– Excl. heating water and packaging
kg
34.0
34.0
34.0
– Incl. heating water
kg
40.1
40.1
40.1
Water capacity
(excl. diaphragm expansion vessel)
l
3.0
3.0
3.0
Max. flow temperature
°C
82
82
82
Max. flow rate
(Limit for the use of hydraulic separation)
l/h
See residual head graph
Nominal circulating water volume
At T
F
/T
R
= 80/60 °C
l/h
818
1076
1374
Diaphragm expansion vessel
Capacity
l
10
10
10
Pre-charge pressure
bar
kPa
0.75
75
0.75
75
0.75
75
Permiss. operating pressure
bar
MPa
3
0.3
3
0.3
3
0.3
Dimensions
Length
mm
360
360
360
Width
mm
450
450
450
Height
mm
700
700
700
Gas connection
R
¾
¾
¾
Standby instantaneous water heater
Hot and cold water connections
G
½
½
½
Permiss. operating pressure (DHW side)
bar
MPa
10
1
10
1
10
1
Minimum pressure, cold water connection
bar
MPa
1.0
0.1
1.0
0.1
1.0
0.1
Outlet temperature, adjustable
°C
30-60
30-60
30-60
Continuous DHW output
kW
26.2
30.4
33.5
Spec. flow rate
At ΔT = 30 K (to EN 13203-1)
l/min
14.45
15.59
17.04
Supply values
Relative to the max. load and 1013 mbar/15 °C
With gas
Natural gas E
m
3
/h
2.89
3.35
3.69
Natural gas LL
m
3
/h
3.36
3.90
4.29
LPG
kg/h
2.12
2.46
2.71
Vitodens 200-W